Growatt 5000MTL -S - User Manual

Growatt 5000MTL -S
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
GR-UM-045-A-02
Growatt 2500MTL-S
Growatt 3000MTL-
Growatt 4200MTL-
Growatt 5000MTL-
Growatt 5500MTL-
S
Growatt 3600MTL-S
S
S
S
Installation
&
Operation Manual
Shenzhen Growatt New Energy Technology CO.,LTD
Building B, Jiayu Industrial Park, #28, GuangHui Road,
Shiyan Street, Baoan District, Shenzhen, P.R.China
T 0755-29515888
F 0755-27472131
E service@ginverter.com
W www.ginverter.com

Questions and Answers

  • N
    nicole42Aug 18, 2025
    What to do if my Growatt 5000MTL -S Inverter shows 'PV Voltage High'?
    • J
      Jennifer FrenchAug 18, 2025
      If your Growatt Inverter displays 'PV Voltage High', it means the DC input voltage is exceeding the maximum tolerable value. Immediately disconnect the DC switch.
  • M
    Meredith GarciaAug 20, 2025
    What causes 'No AC Connection' error in Growatt 5000MTL -S and how to fix it?
    • S
      stacey47Aug 20, 2025
      The 'No AC Connection' error on your Growatt Inverter indicates that there is no utility grid connected or a utility grid power failure. Check the AC wiring.
  • F
    Fernando MosleyAug 23, 2025
    Why does my Growatt Inverter display 'AC V Outrange'?
    • P
      Pamela GravesAug 23, 2025
      The 'AC V Outrange' error on your Growatt Inverter means the utility grid voltage is out of the permissible range. Check the grid voltage. If the error persists despite the grid voltage being within the acceptable range, contact Growatt.
  • K
    kelly69Aug 26, 2025
    What does 'AC F Outrange' mean on my Growatt Inverter?
    • C
      Christine BlanchardAug 26, 2025
      The 'AC F Outrange' error on your Growatt Inverter indicates that the utility grid frequency is out of the permissible range. Check the grid frequency. If the error continues even when the grid frequency is within the acceptable range, contact Growatt.
  • U
    uoneillAug 28, 2025
    What does Error 111 mean on a Growatt 5000MTL -S Inverter, and how do I fix it?
    • T
      Toni DuncanAug 28, 2025
      Error 111 on a Growatt Inverter indicates a PE abnormality. Here’s how to troubleshoot: * Check the PE line to ensure it has good contact. * Verify that the L and N lines are not reversed. * Restart the inverter. If the error persists, contact Growatt.
  • R
    rlopezAug 30, 2025
    What does 'Over Temperature' mean on Growatt 5000MTL -S Inverter?
    • C
      Chad CarpenterAug 30, 2025
      The 'Over Temperature' error on your Growatt Inverter indicates that the temperature is out of range. Check the inverter operation state. If the error message is still displayed, please contact Growatt.
  • N
    nicholas81Sep 2, 2025
    What does 'PV Isolation Low' mean on a Growatt Inverter?
    • S
      Sean WilsonSep 2, 2025
      The 'PV Isolation Low' error on your Growatt Inverter suggests an insulation problem. Check the following: * If the panel enclosure is properly grounded. * If the inverter is properly grounded. * If the DC breaker is wet. If the error persists after checking these, contact Growatt.
  • O
    Olivia ReyesSep 4, 2025
    What does Error 102 mean on a Growatt 5000MTL -S Inverter, and how can I resolve it?
    • J
      john53Sep 4, 2025
      Error 102 on a Growatt Inverter is a consistent fault indicating that the data received by the Master and Slave processors are different, possibly due to frequent changes in utility grid voltage or frequency. Try restarting the inverter. If the error appears frequently or persists after restarting, check the utility grid. If the error still exists, contact Growatt.
  • A
    Alex RiveraSep 7, 2025
    What does 'Output High DCI' mean on Growatt Inverter?
    • A
      Ashley MaciasSep 7, 2025
      The 'Output High DCI' error on your Growatt Inverter indicates that the output current DC offset is too high. Restart the inverter. If the error message still exists, contact Growatt.
  • K
    kriosSep 9, 2025
    What does Error 121 mean on a Growatt 5000MTL -S Inverter, and how do I fix it?
    • J
      jromanSep 9, 2025
      Error 121 on a Growatt Inverter indicates a communication fault where the Master processor can't receive data from the Slave processor. To resolve this, restart the inverter. If the error message persists, contact Growatt.

Summary

Safety

General Safety Instructions

Crucial safety guidelines and warnings for installation and operation.

Installation

Safety instructions

Crucial safety guidelines for installation.

Electrical Connection

Safety

Essential safety precautions for electrical work.

Trouble shooting

Errors (E)

Diagnosing fault codes and potential solutions.

Assembly Warnings

Electrical Connection Warnings

Growatt 5000MTL -S Specifications

General IconGeneral
Model5000MTL-S
Rated Power5000 W
Max. PV Input Power6000 W
Nominal DC Voltage360 V
Number of MPPT2
Number of MPP Trackers2
Max DC Input Current11 A
Max. Input Current per MPPT11 A
Nominal AC Power5000 W
Max. AC Power5500 W
Max. AC Current22.7A
AC Voltage Range180-280V
Nominal Grid Frequency50/60Hz
AC Output Frequency50 / 60 Hz
Power Factor>0.99
THDi<3%
Peak Efficiency98.4%
DC Connection TypeMC4
AC Connection TypeTerminal Block
Protection DegreeIP65
TopologyTransformerless
Cooling MethodNatural Cooling
Weight12.8 kg
AC Output Voltage230V
Protection LevelII
Operating Temperature Range-25°C to 60°C
Operating Temperature-25°C to 60°C
CoolingNatural