Growatt 5500MTL-S - User Manual

Growatt 5500MTL-S
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
GR-UM-045-A-02
Growatt 2500MTL-S
Growatt 3000MTL-
Growatt 4200MTL-
Growatt 5000MTL-
Growatt 5500MTL-
S
Growatt 3600MTL-S
S
S
S
Installation
&
Operation Manual
Shenzhen Growatt New Energy Technology CO.,LTD
Building B, Jiayu Industrial Park, #28, GuangHui Road,
Shiyan Street, Baoan District, Shenzhen, P.R.China
T 0755-29515888
F 0755-27472131
E service@ginverter.com
W www.ginverter.com

Questions and Answers

  • A
    Anna HarrisAug 18, 2025
    What to do if my Growatt Inverter shows 'PV Voltage High'?
    • C
      Christine JohnsonAug 18, 2025
      If your Growatt Inverter displays 'PV Voltage High', it means the DC input voltage is exceeding the maximum tolerable value. Immediately disconnect the DC switch.
  • A
    Anne RodriguezAug 20, 2025
    What causes 'No AC Connection' error in Growatt 5500MTL-S Inverter and how to fix it?
    • D
      Danielle MartinezAug 20, 2025
      The 'No AC Connection' error on your Growatt Inverter indicates that there is no utility grid connected or a utility grid power failure. Check the AC wiring.
  • Q
    qmcculloughAug 23, 2025
    Why does my Growatt Inverter display 'AC V Outrange'?
    • K
      Kelly GrantAug 23, 2025
      The 'AC V Outrange' error on your Growatt Inverter means the utility grid voltage is out of the permissible range. Check the grid voltage. If the error persists despite the grid voltage being within the acceptable range, contact Growatt.
  • C
    Carol KingAug 26, 2025
    What does 'AC F Outrange' mean on my Growatt 5500MTL-S Inverter?
    • C
      Cindy CaldwellAug 26, 2025
      The 'AC F Outrange' error on your Growatt Inverter indicates that the utility grid frequency is out of the permissible range. Check the grid frequency. If the error continues even when the grid frequency is within the acceptable range, contact Growatt.
  • A
    Andrew CookAug 28, 2025
    What does Error 111 mean on a Growatt 5500MTL-S, and how do I fix it?
    • C
      Christine BurgessAug 28, 2025
      Error 111 on a Growatt Inverter indicates a PE abnormality. Here’s how to troubleshoot: * Check the PE line to ensure it has good contact. * Verify that the L and N lines are not reversed. * Restart the inverter. If the error persists, contact Growatt.
  • D
    Dawn MillerAug 30, 2025
    What does 'Over Temperature' mean on Growatt 5500MTL-S?
    • D
      douglas02Aug 30, 2025
      The 'Over Temperature' error on your Growatt Inverter indicates that the temperature is out of range. Check the inverter operation state. If the error message is still displayed, please contact Growatt.
  • C
    Christopher MorrisSep 2, 2025
    What does 'PV Isolation Low' mean on a Growatt Inverter?
    • I
      Ian BrownSep 2, 2025
      The 'PV Isolation Low' error on your Growatt Inverter suggests an insulation problem. Check the following: * If the panel enclosure is properly grounded. * If the inverter is properly grounded. * If the DC breaker is wet. If the error persists after checking these, contact Growatt.
  • M
    michael52Sep 4, 2025
    What does Error 102 mean on a Growatt 5500MTL-S, and how can I resolve it?
    • A
      Anne EllisSep 4, 2025
      Error 102 on a Growatt Inverter is a consistent fault indicating that the data received by the Master and Slave processors are different, possibly due to frequent changes in utility grid voltage or frequency. Try restarting the inverter. If the error appears frequently or persists after restarting, check the utility grid. If the error still exists, contact Growatt.
  • J
    Joseph DavisSep 7, 2025
    What does 'Output High DCI' mean on Growatt Inverter?
    • T
      Timothy SotoSep 7, 2025
      The 'Output High DCI' error on your Growatt Inverter indicates that the output current DC offset is too high. Restart the inverter. If the error message still exists, contact Growatt.
  • M
    Matthew TaylorSep 9, 2025
    What does Error 121 mean on a Growatt 5500MTL-S Inverter, and how do I fix it?
    • T
      tpetersonSep 9, 2025
      Error 121 on a Growatt Inverter indicates a communication fault where the Master processor can't receive data from the Slave processor. To resolve this, restart the inverter. If the error message persists, contact Growatt.

Summary

Safety

2.1 Intended Use

Unit converts DC to grid-compliant AC for single-phase feed-in into electricity grid.

2.2 Qualification of skilled person

Grid-tied inverter system operates only when connected to AC distribution network by qualified personnel.

2.3 Safety instruction

Inverters designed to international safety requirements, but precautions must be observed.

2.4 Assembly Warnings

Inspect for damage, assemble per instructions, use care with location, and cover array with dark material.

2.5 Electrical Connection Warnings

Discusses grounding of PV modules for transformerless inverters and compliance with local requirements.

Installation

5.1 Safety instructions

Safety instructions for installation, including danger to life due to fire or explosion.

5.3 Mounting the Inverter

Instructions on how to securely mount the inverter on a wall using different types of brackets.

Electrical connection

6.1 Safety

Safety precautions for electrical connection, including lethal voltages and electrostatic discharge.

6.2 Wiring AC Output

Details on wiring the AC output, including circuit breaker recommendations and wiring steps.

Start-Up and shut down the inverter

8.1 Start-Up the inverter

Steps to start up the inverter, including connecting AC breaker and turning on the DC switch.

8.2 Turn-off the Inverter

Steps to shut down the inverter, emphasizing not disconnecting DC connectors under load.

Trouble shooting

10.1 Warnings(W)

Explains warnings that identify current status but not faults, and how they are cleared.

Manufacturer Warranty

Growatt 5500MTL-S Specifications

General IconGeneral
Model5500MTL-S
Rated Power5500 W
Nominal DC Voltage360 V
Number of MPPT2
Number of DC Inputs2
Max. Input Current per MPPT11 A
Nominal AC Power5500W
Max. AC Power5500 W
Max. Output Current25 A
Nominal AC Voltage230 V
Output Voltage230 V
AC Voltage Range180-280V
Nominal Grid Frequency50/60Hz
Frequency50/60Hz
Power Factor>0.99
THDi<3%
Max. Efficiency97.6%
Efficiency97.6%
DC SwitchYes
Protection DegreeIP65
Protection ClassI
Operating Temperature Range-25 °C to +60 °C
Weight10.8 kg
Cooling MethodNatural Cooling
CoolingNatural Cooling
Max DC Input Current11 A
European Efficiency97.0%
Operating Temperature-25°C to +60°C
CommunicationRS485, Wi-Fi