Off Grid Solar Inverter
SPF 3500 ES
SPF 5000 ES
Version: 4.0
User Manual

Other manuals for Growatt SPF 5000 ES

Questions and Answers

  • R
    richard66Jul 31, 2025
    What to do if my Growatt SPF 5000 ES Inverter has no response after power on?
    • S
      Susan EdwardsJul 31, 2025
      If your Growatt Inverter shows no response after being powered on, it could be due to these reasons: * The battery voltage is extremely low (less than 1.4V/Cell). * The battery polarity is reversed. Here’s how to address it: 1. Check the connections of the batteries and wiring to ensure they are secure. 2. Recharge the battery. 3. If the issue persists, replace the battery.
  • B
    Briana OwensAug 6, 2025
    What to do if my Growatt SPF 5000 ES Inverter works in battery mode even when mains exist?
    • O
      Olivia VillaAug 7, 2025
      If your Growatt Inverter continues to operate in battery mode despite the presence of mains power, there are several possible causes: * The input protector may be tripped. Check if the AC breaker has tripped and ensure the AC wiring is properly connected. * The AC power quality might be insufficient, especially if using shore power or a generator. Verify that the AC wires are not too thin or too long. If using a generator, confirm it's functioning correctly and that the input voltage range setting is correct (UPS? Appliance). * Alternatively, try changing the output source priority to Utility first.
  • K
    Kristen McphersonAug 13, 2025
    What to do if Growatt SPF 5000 ES Inverter shuts down automatically during startup?
    • S
      Sandra BrownAug 13, 2025
      If your Growatt Inverter shuts down automatically during the startup process, it's likely due to low battery voltage (less than 1.91V/Cell). To resolve this: 1. Re-charge the battery. 2. If re-charging doesn't solve the issue, replace the battery.
  • J
    jamiehawkinsAug 18, 2025
    Why is the internal relay in my Growatt Inverter switching on and off repeatedly?
    • J
      Jeffrey DudleyAug 18, 2025
      If the internal relay of your Growatt Inverter is repeatedly switching on and off when turned on, it might be because the battery is disconnected. Check the battery wires to ensure they are properly connected.
  • S
    Stacy BoydOct 25, 2025
    Why is my Growatt Inverter beeping continuously and the red LED is on?
    • W
      William GarciaOct 25, 2025
      A continuous beep and a red LED on your Growatt Inverter indicate a fault. Here’s what the different fault codes mean: * Fault code 01: Replace the fan. * Fault code 02: Check for blocked airflow or high ambient temperature. * Fault code 03, 08/09/53/57, 51, 56: Return to repair center. * Fault code 05: Check wiring and remove any abnormal loads. * Fault code 06/58: Reduce the connected load or return to repair center. * Fault code 07: Reduce the connected load by switching off some equipment. * Fault code 60: Check if the AC output is connected to the grid input, verify Program 8 settings for all parallel inverters, ensure current sharing cables are properly connected in the same parallel phases, and confirm all neutral wires of all parallel units are connected. If the prob...

Summary

Information on this Manual

Safety Instructions

Essential safety guidelines and precautions for operating the inverter.

Product Overview

Installation

Mounting the Unit

Guidelines for selecting an installation location and mounting the inverter securely.

Battery Connection

Lead-acid Battery Connection

Step-by-step instructions for connecting lead-acid battery banks to the inverter.

AC Input;Output Connection

PV Connection

LCD Display Icons

Display Information

Operating Mode Description

Wiring Connection

Parallel Operation in Single Phase

Parallel Operation in Three Phase

Parallel in Single Phase

Parallel in Three Phase

Fault Reference Code

Warning Indicator

Battery Equalization

Specifications

Trouble Shooting

Growatt SPF 5000 ES Specifications

General IconGeneral
ModelSPF 5000 ES
Rated Power5000W
Input Voltage230 VAC
Output Voltage230 VAC
Max PV Array Power6000W
Max PV Input Voltage450 VDC
Battery Voltage48 VDC
Surge Power10000VA
Max. Charging Current100A
AC Charging Current60A
Number of MPPTs1
Efficiency93%
Frequency50 Hz/60 Hz
MPPT Voltage Range120 VDC - 430 VDC
Communication InterfaceUSB/RS232
Dimensions330 x 485 x 135 mm