42
No AC connection
Error: 302
No AC connection
Check AC wiring.
Check the status of AC breaker
AC F Outrange
Error: 303
Utility grid frequency out of
permissible range.
Please switch off DC switch.
Check AC wiring, especially neutral and
ground wire.
Check grid frequency is complied with local
grid standard. Restart inverter, if problem
still exist, Contact Growatt.
PE abnormal
Error: 304
Voltage of Neutral and PE above
30V.
1. Check the voltage of Neutral and PE.
2. Check AC wiring.
3. Restart inverter, if error message still
exisits,contact Manufacturer
Auto Test Failed
Error: 407
Auto test didn’t pass.
Restart inverter, repeat Auto Test, if
problem still exist, contact Growatt.

Other manuals for Growatt MIN 4200TL-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt MIN 4200TL-X and is the answer not in the manual?

Growatt MIN 4200TL-X Specifications

General IconGeneral
Product colorWhite
Overvoltage categoryCAT II
Power protection featuresOver voltage, Reverse polarity, Short circuit
International Protection (IP) codeIP65
Noise level35 dB
Product type-
Maximum power4200 W
Output current19 A
Number of phases1
Output frequency50/60 Hz
Starting voltage100 V
MPP voltage range80 - 550 V
Output power capacity (max)4.2 kVA
Input operation voltage (max)550 V
Input operation voltage (min)80 V
Output operation voltage (max)280 V
Output operation voltage (min)180 V
Total Harmonic Distortion (THD)3 %
Wi-FiYes
Display technologyOLED
Operating temperature (T-T)-25 - 60 °C
Weight and Dimensions IconWeight and Dimensions
Depth160 mm
Width375 mm
Height350 mm
Weight10800 g