47
*Only for Australia market.
7.4.2 USB-A
USB-A port is mainly for connecting monitor or firmware updage
Through USB connection,we can connect external optional monitor ,for
example :Shine WIFI-X,Shine 4G-X, Shine LAN-X,ect.
And also you can quickly update the software by U stick.
We can monitor as below:
Make sure the on the front side, then insert the monitor,
fasten the screw.
8 Start-Up and shut down the inverter
8.1 Start-Up the inverter
1. Connect the AC breaker of the inverter.
2. Turn on the dc switch, and the inverter will start automatically when the input
voltage is higher than 60 V.
8.2 Shut down the Inverter
DANGER
Do not disconnect the DC connectors under load.