| Type | Centrifugal Pump |
|---|---|
| Liquid Temperature | -20°C to +120°C |
| System Pressure | Max 25 bar |
| Pump Housing | Stainless Steel |
| Impeller | Stainless Steel |
| Motor Type | Asynchronous motor |
| Frequency | 50/60 Hz |
| Protection Class | IP55 |
| Insulation Class | F |
| Max Head | Up to 160 m |
| Motor Power | 0.37 kW |
| Approvals | CE, EAC |
Explains hazard symbols and statements for safety.
Lists maximum allowed inlet and operating pressures for pump models.
Procedures for mounting the pump and connecting inlet/outlet pipes.
Tables specifying flange force and torque limits for pump mounting.
Discusses temperature rise risks and electrical connection safety.
Guidelines for safe electrical connections and wiring according to codes.
Details on motor types, terminal box positioning, and motor protection.
Safety precautions and steps for filling and venting the pump.
Step-by-step instructions for starting the pump correctly.
Guidelines for efficient operation and important safety warnings.
Causes and remedies for when the pump fails to run.
Causes and remedies for reduced pump performance or no water delivery.
Causes and remedies for blown fuses, tripped breakers, or overload relays.