English (GB)
18
7.15.3 Configuration with the PC Tool E-products
Find the desired configuration file in the PC Tool E-products in 
this way:
1. Start PC Tool.
2. Find the desired configuration file in the PC Tool E-products in 
one of these ways:
• Search by the configuration number. See fig. 49.
• Search on the basis of the application that MGE is part of.
• Choose the file position on the PC hard disk via the PC Tool 
E-products browser.
Searching by configuration number
Fig. 49 Configuration of terminal box by searching for the GSC number
3. End PC Tool and remove MI 301.
8. Lubricating the bearings
Lubricate the bearings through the grease nipples with a grease 
dispenser and high-temperature grease as specified on the 
bearing nameplate.
The display indicates the number of bearing relubrications that 
has been done since the last bearing replacement. For more 
information about the display, see the installation and operating 
instructions:
The factory-set interval between relubrications is stated on the 
bearing nameplate placed on the motor. The relubrication interval 
can be changed by a Grundfos service technician.
It is possible to relubricate the bearings five times according to 
the preset interval. When the preset interval has been reached 
after the fifth relubrication, a warning will be given to replace the 
bearings.
In the case of seasonal operation (motor is idle for more than six 
months of the year), we recommend that you lubricate the motor 
bearings when you take it out of operation.
It is important to relubricate the bearings as specified on the 
motor nameplate with mechanical data. If this interval is not 
observed, the bearing life will be reduced.
Reduced lubricating interval
The lubricating interval must be reduced in these situations:
• Dirty and dusty environments. Reduce the lubricating interval 
by a factor 0.75.
• Very moist environments. Reduce the lubricating interval by a 
factor 0.9.
If the environments are both dusty and moist, multiply the factors.
Grease type and quantity
See the bearing nameplate.
TM04 2563 2608
1. Select "Standard configuration".
2. Select "Number".
3. Enter a number or part of a 
number.
4. Click [Search now].
5. Select the configuration file in the 
list of search results.
6. Click [Send] to download the 
configuration file to the MGE.
http://net.grundfos.com/qr/i/98246988
Never mix grease with thickeners, such as 
lithium-based grease with polycarbamide-based 
grease.