EasyManua.ls Logo

Grundfos MQ Series - Suction Lift Performance; Mechanical Installation

Grundfos MQ Series
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
English (US)
7. Operating conditions
7.1 Suction lift
The maximum suction lift of the pump can be
determined from the diagram, page 19.
Example:
If the suction lift is 10 ft, the length of the suction pipe
must not exceed 72 ft.
MQ 3-35 MQ 3-45
Maximum flow rate [gpm] 22
Maximum inlet pressure [psi] 40
Pump discharge range [psi] 15-49 18-63
Maximum combined discharge pressure: Max.
Inlet + pump discharge range [psi]
55-89 58-103
Maximum suction lift [ft]; see page 19 25
Minimum ambient temperature [°F]/[°C] 32/0
Maximum ambient temperature [°F]/[°C] 113/45
Minimum liquid temperature [°F]/[°C] 32/0
Maximum liquid temperature [°F]/[°C] 95/35
Net weight [lbs] 29
Sound pressure level [dB(A)] < 70
Tank volume [oz] 13.5
Air pressure in tank [psi] 22 to 25
Connections 1" NPT
Priming and drain plugs 3/8" GAS

Related product manuals