The functions of the control panel are described in the following table:
Illustration Description
1 Indicator light (red):
When the indicator light is on, the pump is on standby.
2 On/off button:
The pump is started/stopped by means of the on/off button.
The on/off button can also be used for manual resetting in
case of an alarm condition:
press once for resetting and
press once more for starting.
3 Indicator light (green):
Indicates that the pump is ready for operation.
When the indicator light is on, the pump will start automatically
when water is consumed. The pump will stop a few seconds
after the water consumption has ceased.
4 Pump on (green):
The indicator light is on when the pump is running.
5 Auto-reset (green):
As standard, this function is activated on delivery (does not
apply to pump versions for Australia).
When the indicator light is
on, the Auto-reset function is activated. The pump will
automatically attempt to restart every 30 minutes after an
alarm/fault over a period of 24 hours. After this period, the
pump will remain in the alarm condition.
off, the Auto-reset function is deactivated. The pump will
not restart after an alarm/fault.
The Auto-reset function can be activated/deactivated by
pressing the on/off button for 5 seconds.
Note: When water is consumed, the pump will start and stop
automatically, whether the Auto-reset light is on or off.
6 Alarm (red):
The indicator light is on when the pump is in alarm condition.
The alarm condition may have been caused by:
dry running,
overtemperature,
overloaded motor,
seized-up motor/pump or
frequent starts/stops (the indicator light flashes).
See section 5.2 Pump stop.
Note
The pump settings are stored. After supply failure, the pump will automatically revert to its