English (GB)
11
4.2 Electrical data
4.3 Dimensions
See dimensions at the end of these instructions.
4.4 Approvals
Materials in contact with the pumped liquid have
been approved by the British Water Regulations
Advisory Scheme (WRAS) according to BS 6920 for
use in drinking water.
Other approvals: See pump nameplate.
5. Functions
5.1 Control panel
The MQ pump is operated entirely by means of the
control panel. See fig. 2. The control panel offers the
possibility of starting/stopping the pump. The pump
settings and operating condition are indicated by
indicator lights.
Fig. 2
MQ 3-25 MQ 3-35 MQ 3-45
Enclosure class IP54
Insulation class B
Supply cable 2 m H07RN-F with/without plug
50 Hz:
Voltage [VAC] 1 x 220-240 V - 10/+ 6 %
Power consumption, P
1
[W] 600 850 1000
60 Hz:
Voltage,
power consumption, P
1
[W]
1 x 110-120 V - 10/+ 6 % - 800 1000
1 x 220-240 V - 10/+ 6 % 550 850 1050
TM01 9684 2600