11. MQ frequently asked questions
1. What causes the MQ to start?
Answer: The MQ is equipped with both an internal
ow switch and pressure switch. Each of these can
turn the MQ on depending on water consumption.
The pump will start when:
The ow rate is greater than 0.3 gpm
OR
the pressure is below 29 psi.
2. What causes the MQ to stop?
Answer: Other than the manual on/o button,
only the ow switch is authorized to automati-
cally stop the MQ during normal operation when
ow drops below 0.3 gpm. The pump will shut o
in 12-15 seconds after ow stops.
Additionall
y, the MQ will be turned o in the
event of a dry-run or over temperature alarm.
3. What is the maximum height of a tap above the
MQ?
Answer: If a tap or faucet is installed at heights
greater than 50 ft above the MQ, there is the po-
tential risk that the MQ will never start. In cases
where the MQ starts due to low pressure (low ow
rates), the pressure has to fall below the pressure
switch activation point (28-30 psi factory setting).
To allow for the pressure o
f 50 ft of water, toler-
ances
and a safety margin, we recommend a maxi-
mum height of 50 ft between the MQ and any tap.
4. What is the purpose of the built-in pressure tank?
Answer: The built-in pressure tank comes from the
factory pressurized at approximately 23 psi (with
the pump pressure at zero), and holds a volume of
5 ounces of water. It is designed to minimize mo-
tor startup due to small leaks.
5. How is the dry-run condition determined?
Answer: The dry-run alarm is declared w
hen the
motor
is running AND the ow rate is less than
0.3 gpm AND when pressure is less than the pres-
sure switch setting. When this condition lasts for
1 minute, the alarm is declared and the motor is
stopped. The MQ attempts to automatically re-
start every 30 minutes for a maximum of 24 hours.
If more than 24 hours pass without water, the
pump must be restarted manually.
6. What is the maximum inlet pressure allowed in
the MQ?
Answer: For both MQ 3-35 and MQ 3-45 the maxi-
mum internal pressu
re allowed is 109 psi. The
maximum inlet pressure when added to the MQ
pressure must not exceed 109 psi.
Remember that inlet pressure adds to the MQ
pressure, so with a 40 psi inlet pressure supplied
to the MQ 3-45, internal pressures can reach ap-
proximately 105 psi (65 + 40 psi).
Additionally, if inlet pressures exceed the built-in
pressure switch activation point, (28-30 psi factory
setting) the pressure switch will be unable to acti-
vate, and the ability to turn the MQ on at low ow
rates
will be lost. In this situation, only the ow
switch will be able to turn the MQ on at ow rates
above its activation point of 0.3 gpm.
7. Where can a pressure gauge be easily installed?
Answer: In the ½" straight thread opening used to
add priming water to the pump.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos SQFlex 11 SQF-2 and is the answer not in the manual?

Grundfos SQFlex 11 SQF-2 Specifications

General IconGeneral
Voltage Range30-300 VDC / 90-240 VAC
MaterialStainless Steel
Supply Voltage30-300 VDC / 90-240 VAC
Enclosure ClassIP68
Motor TypePermanent Magnet Motor
Protection ClassIP68
Weight15 kg
Pump TypeSubmersible
Liquid Temperature Range0°C to +40°C
Maximum Submersion Depth150 m
Operating Temperature Range0°C to +40°C