EasyManuals Logo

Gude Expert Power Control 8042 Series User Manual

Gude Expert Power Control 8042 Series
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #76 background imageLoading...
Page #76 background image
76
Expert Power Control 8042
© 2020 GUDE Systems GmbH
Specifications
The command "port all state {MODE0=0|MODE1=1|MODE2=2} show" returns the
switching state of all relays in 3 possible formats.
e) Switching Port Relays
#port all state set "1,2,12" 1
OK.
The command syntax "port all state set "{port_list}" {OFF=0|ON=1}" sets a list of ports
to ON=1 or OFF=0.
4.7.1
Console Cmd 8042
Command
Description
Note
logout
go to login prompt when enabled
2
quit
quits telnet session - nothing in serial console
2
back
back one cmd level
2
help
show all cmds from this level
2
help all
show all cmds
2
clock
enters cmd group "clock"
clock enabled set {OFF=0|ON=1}
enables ntp
clock enabled show
shows if ntp enabled
clock timezone set {minutes}
sets timezone
clock timezone show
shows timezone
clock dst enabled set {OFF=0|ON=1}
enables dst
clock dst enabled show
shows if dst is enabled
clock manual set "{hh:mm:ss yyyy-mm-dd}"
sets time and date manually
clock show
shows actual time and date
clock ntp server {PRIMARY=0|BACKUP=1} set
"{dns_name}"
sets ntp server name
clock ntp server {PRIMARY=0|BACKUP=1} show
shows ntp server name
console
enters cmd group "console"
console version
shows unique console version number
console telnet enabled set {OFF=0|ON=1}
enables telnet on/off
console telnet enabled show
shows if telnet enabled
console telnet port set {ip_port}
sets telnet port
console telnet port show
shows telnet port
console telnet raw set {OFF=0|ON=1}
sets raw mode (disables editing) on/off
console telnet raw show
shows if raw mode enabled
console telnet echo set {OFF=0|ON=1}
enables echo on/off
console telnet echo show
shows if echo enabled
console telnet activeneg set {OFF=0|ON=1}
enables telnet active negotiation (IAC) on/off
console telnet activeneg show
shows if active negotiation enabled
console telnet login set {OFF=0|ON=1}
enables login on/off
console telnet login show
shows if login enabled
console telnet login local set {OFF=0|ON=1}
enables local login on/off
console telnet login local show
shows if local login enabled
console telnet login radius set {OFF=0|ON=1}
enables login for RADIUS on/off
console telnet login radius show
shows if RADIUS login enabled
console telnet login delay set {OFF=0|ON=1}
enables delay (after 3 login fails) on/off
console telnet login delay show
shows if login delay enabled
console telnet user set "{username}"
sets login user name
console telnet user show
shows login user name
console telnet passwd set "{passwd}"
sets login password
console telnet passwd hash set "{passwd}"
sets login hashed password
console serial enabled set {OFF=0|ON=1}
enables serial console on/off
console serial enabled show
shows if serial console enabled
console serial raw set {OFF=0|ON=1}
sets raw mode (disables editing) on/off
console serial raw show
shows if raw mode enabled
console serial echo set {OFF=0|ON=1}
enables echo on/off
console serial echo show
shows if echo enabled
console serial kvm set {OFF=0|ON=1}
enables binary KVM cmds on serial port on/off
console serial kvm show
shows if binary KVM cmds enabled
console serial utf8 set {OFF=0|ON=1}
enables UTF8 support
console serial utf8 show
shows if UTF8 enabled
console serial login set {OFF=0|ON=1}
enables login on/off

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gude Expert Power Control 8042 Series and is the answer not in the manual?

Gude Expert Power Control 8042 Series Specifications

General IconGeneral
BrandGude
ModelExpert Power Control 8042 Series
CategoryController
LanguageEnglish