To set the stepless rotary control
1
of the room
thermostat to the desired room temperature, please
proceed as follows:
1. Set the rotary control
1
to max.
2. Let the unit run until the desired room tempera
-
ture is reached.
3. Slowly turn the control dial
1
back until the
unit switches o.
The unit now regulates the room temperature auto
-
matically via the room thermostat by automatically
switching o when the set temperature is exceeded
and switching on again when the temperature falls
below this set temperature. To do this, heating level 1
or 2 must be set on function controller
2
.
Note
The desired room temperature should be higher than
the current room temperature.
Note
The operating control light
3
lights up when the
thermostat is set to a temperature above the room
temperature via the control dial
1
and at the same
time the ventilation or a heating level is set on the
function control
2
. If the unit is o, i.e. the function
control
2
is set to position 0, the operating control
light
3
does not light up.
Switch o the unit
1. Set the stepless rotary control
1
of the room
thermostat to min.
2. Set the function control
2
to ventilation
3. Let the fan run for 2-3 minutes to cool down
the unit.
4. Switch the unit o by setting the function
control
2
to 0.
5. Unplug the mains cable from the mains socket.
6. Allow the unit to cool down completely.
Troubleshooting
Problem Cause Solution
Unit without
function
Unit has no power
supply
Check the socket
Plug in the mains
plug correctly
Check house fuse
Check mains cable
and plug
Unit, mains cable
or mains plug is
defective
Contact customer
service or a spe
-
cialist
The overheating
protection has been
triggered
Switch o the
appliance and
disconnect the
mains plug.
Contact the
customer service or
a specialist
Unit does not
heat
No heating level set Set heating level
The room temp. is
above the tempe
-
rature set on the
thermostat.
Increase the ther
-
mostat temperature
The safety thermo
-
stat has tripped
Switch o the unit
and disconnect the
mains plug.
Eliminate the cause
of overheating
before restarting
the appliance.
The overheating
protection has been
triggered
Switch o the unit
and disconnect the
mains plug.
Contact customer
service or a spe
-
cialist
The anti-tilt
protection has been
triggered
Ensure that the
unit is positioned
vertically and is not
exposed to extreme
inclination
Reduced air
ow
Air inlet and outlet
not free
Clean and observe
minimum distances