11
Work Hints For Your All Purpose Saw
If your power tool becomes too hot, set the speed to maximum and run a no load for 2-3
minutes to cool the motor.
Always ensure the work-piece is firmly held or clamped to prevent movement.
The pivot foot plate must be held firmly against the material being cut to reduce saw
vibration, blade jumping and blade breakage.
Maintenance
Trouble Shooting
Remove the plug from the socket before carrying out any adjustment, servicing or maintenance.
Your power tool requires no additional lubrication or maintenance.
There are no user serviceable parts in your power tool. Never use water or chemical
cleaners to clean your power tool. Wipe clean with a dry cloth. Always store your power
tool in a dry place. Keep the motor ventilation slots clean. Keep all working controls free
of dust. Occasionally you may see sparks through the ventilation slots. This is normal
and will not damage your power tool.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid a hazard.
1.If your all purpose saw will not operate, check plug fuse and power at mains plug.
2.There are no user serviceable parts in the saw other than those listed in Care and
Maintenance.
3.If a fault is suspected return to an authorised dealer for repair.
Technical Data
Voltage 230V-240V~50 Hz
Power input 500 W
No load speed 500-3000 /min
Stroke length 13mm
Max. Cutting capacity in wood 100 mm
Protection class
/II
Machine weight 2.43 kg
Technical Data Table