Type | Slit Lamp |
---|---|
Mounting | Table-mounted |
Illumination | LED |
Slit Width | 0 to 14 mm |
Filters | Cobalt blue |
Power Supply | AC 100-240V |
Magnification | 10x |
Safety warning regarding who can perform tonometry.
Crucial safety advice to read manual before product use.
Regulatory note for USA market concerning device sales.
Notes on the use of decimal separators in the instructions.
Specifies operating and storage environmental conditions for the device.
Procedures for safe handling and unpacking of the device during shipping.
Important warnings regarding device installation and modifications.
Safety guidelines for performing examinations and device usage.
Notes on operator qualifications and responsibilities for device use.
Clarification on the disinfection requirements for the tonometer itself.
Detailed procedures and warnings for cleaning and disinfecting the measuring prism.
Critical danger warning about using damaged measuring prisms.
Warning and guidelines on the safe usage period for reusable prisms.
Introduction to Tonosafe disposable prisms for hygiene and convenience.
Requirement for monthly checks and actions after external force application.
Conditions for product use and warranty voidance due to improper handling.
Obligation to report serious incidents involving the device to authorities.
Description of the applanation tonometers and who can use them.
Details medical purpose, indications for glaucoma, and contraindications.
Explains operation principles and suitable operating environments.
Highlights the clinical benefits of Goldmann Applanation Tonometry.
Provides a general overview and lists key components of the tonometer.
Critical warning that only trained specialists should perform installation and repairs.
Step-by-step assembly instructions for the AT 900 model R on BM 900 slit lamp.
Instructions for mounting the AT 900 model T on the slit lamp.
Instructions for connecting the AT 900 model BQ to the slit lamp.
Note regarding compatibility and instructions for other manufacturers' devices.
Table detailing compatibility of different Haag-Streit slit lamps with AT 900 and AT 870 tonometers.
Description of AT 900 R model installation and observation method.
Description of AT 900 T model positioning and observation.
Description of AT 900 BQ model features and examination method.
Description of AT 870 model positioning and operation.
Crucial warning to read safety chapter before operating the device.
Note on ensuring smooth operation with original accessories.
Warning regarding mandatory cleaning and disinfection of reusable prisms.
Guidance on measuring astigmatism and its effect on measurement methodology.
Explanation of the Goldmann method for measuring intraocular pressure.
Instructions for preparing the patient, including anaesthesia and fluorescein application.
Guidance for patients on how to position themselves and cooperate during the examination.
Steps for preparing the slit lamp and tonometer before measurement.
Note on ensuring the tonometer arm moves freely without obstruction.
Warning about incorrect eyepiece adjustment leading to inaccurate measurements.
Identifies errors related to incorrect fluorescein bands and patient distance.
Details errors caused by incorrect horizontal and vertical positioning.
Explains errors due to applying incorrect pressure during measurement.
Describes error images for high/low positioning and correct setting.
Describes error images for incorrect pressure and correct setting.
Provides technical specifications for the AT 900 applanation tonometer.
Details measuring force and installation for the AT 870.
Specifies the measurement range and deviation for the AT 870.
Lists backlash width and net weight for the AT 870.
Critical warning about performing maintenance and repairs by trained personnel only.
General guidance on device repairs and the need for qualified technicians.
Procedures for cleaning and disinfecting the tonometer housing and sensor arm.
Requirement for monthly checks of the AT 900 tonometer.
Instruction to send defective devices for repair to the representative.
Procedure for checking drum position 0 on the AT 900.
Procedure for checking drum position 2 on the AT 900 using control weight.
Requirement for monthly checks of the AT 870 tonometer.
Instruction to send defective devices for repair to the representative.
Procedure for checking drum position 6 on the AT 870.
Procedure for checking position 5.9 on the AT 870 drum.
Procedure for checking position 6.1 on the AT 870 drum.
Procedures for verifying drum positions 0, 1.95, and 2.05.
Procedures for verifying drum positions 2 and 6.
Procedures for verifying drum positions 5.9 and 6.1.
Lists available accessories, functional parts, detachable parts, and consumables.
Information on original prisms and Tonosafe disposable prisms.
Covers legal aspects, classification, and disposal guidelines for the device.
Lists the standards observed in the development and design of the device.