SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION
The incoming air pressure or air
flow is incorrect.
Check the incoming air
supply.
There is a problem with the
voltage to the turret clamp /
unclamp solenoid.
Check the voltage to the
turret clamp / unclamp
solenoid.
There is a problem with the
turret clamp / unclamp
solenoid.
Check the turret clamp /
unclamp solenoid.
There is a problem with the
clamp/unclamp cylinder.
Test the air cylinder for
faulty piston seal.
Alarm 113 Turret failure to reach the Unclamp switch,
Alarm 2022 Turret failure to leave clamp switch, Alarm 8113 Turret
failed to reach the unclamp switch
The turret unclamp sensor is
faulty or out of adjustment.
Check the turret unclamp
sensor.
Turret is out of alignment.
Check Turret/Motor
coupling adjustment.
Mechanical binding of turret.
Check turret for possible
turret o-ring damage or
chip intrusion.
Alarm 114 TURRET failure to reach the Clamp switch Alarm 2023 Turret
failure to leave unclamp switch
The turret clamp sensor is
faulty or out of adjustment.
Check the turret clamp
sensor.
Unusual noise as the turret rotates
Tool Turret Die springs are
broken.
Remove Tool Turret to
inspect or replace springs.
The servo motor has an
electrical fault.
Go to DIY servo system
trouble shooting.
Alarm 106 A-AXIS POSITION ERROR
Mechanical obstruction.
Inspect turret for possible
obstruction or binding
during rotation.
Axis rotating slowly, hesitating to rotate.
Contaminated HPC Pressure
Sensor cable.
Check the HPC Pressure
cable for coolant
contamination.
Turret Indexer Assembly - SL-10/30 ST-10/15 - Troubleshooting Guide
Page 2 of 5 pages