Why is there no soft water after regeneration in my Hague Quality Water Maximizer 410 Water Dispenser?
- JJordan JohnsonJul 31, 2025
If you're not getting soft water from your Hague Quality Water Water Dispenser after regeneration, it could be due to several reasons. First, check if there's enough salt in the brine cabinet and add more if needed. Sediment buildup might be blocking the brine line or air check/draw tube; if so, remove and flush these components, clean the injector assembly, and clear any sediment from the brine cabinet. A plugged flow control can also cause this issue; remove the brine piston housing to clear any debris. Ensure the drain line isn't pinched, frozen, or restricted. A clogged injector assembly requires removing the injector cap and cleaning the nozzle and throat. Finally, a salt bridge may have formed; break it up with a blunt object or use hot water to loosen it.