Operating Specications
1. Read all precautions, installation, and operating instructions carefully and
completely before installing the unit.
2. Do not install this unit where the line pressure may exceed 100 psi. Operating
pressure range: 20psi – 100psi.
3. The rated service ow is seven gallons per minute; rated capacity is
600,000 gallons.
4. Sediment pre-lter cartridges should be changed as needed. (When you can
no longer detect the original white color of the lter, it is time for replacement.
Sediment levels vary greatly, so regular visual inspections are reccommended
during the rst year.)
5. Install on cold water lines only. Operating temperature range: 40° – 90°F.
Protect unit from freezing.
6. Do not install the unit on its side or in direct sunlight. Outdoor installation
requires the use of sunproof sumps. Please contact our sales and service
department (888) 245-3114 to discuss your specic needs.
7. Installation of the system must comply with existing state and local plumb-
ing codes. Hahn is not liable for consequential or incidental damages due
to improper installation.
8. When cleaning – use only warm, soapy water to clean the outside of the hous-
ing. Rinse well with fresh, clean water. Never use chemical cleaning products
on the lter’s exterior surface because they may damage the unit housing.