Performance and curves diagrams
Domestic air conditioner
11.8 Heating suction pressure curves
54
outdoor temp.
(humidity 46%)
DB/WB 10
20
27
15
352 393 413
10
406 437 456
-7/-8
502 543 562
2/1
623 664 683
7/6
759 800 819
12/11
861 902 922
18/16
1031 1072 1092
24/20 1221 1262 1282
performance curves
heating suction pressure.table
indoor temp.
200
400
600
800
1000
1200
1400
15 10-7/-8 2/1 7/6 12/1118/1624/20
suction pressure (kpa)
outdoor temp.(DB.WB)