Domestic air conditioner
55
performance curves
heating suction pressure.table
outdoor temp indoor temp.
DB/WB 10 20 27
-20 126 214 236
-15 220 264 308
-10 210 246 290
-7/-8 262 350 394
2/1 381 469 513
7/6 514 602 646
12/11 554 642 686
18/16 721 809 853
24/20 907 995 1039
heating suction pressure and temp. curves
1100
1000
900
800
700
600
10
500
400
20
300
27
200
100
0
outdoor temp.(DB/WB)
suction pressure (Kpa)