116
Super Match
Item Model AD18MS1ERA/1U18FS2ERA(S
)
Function cooling heating
Capacity KW 5.0(1.8~6) 5.5(2~6.2)
Sensible heat ratio 0.73 /
Total power input KW 1.55(0.55~2.0) 1.48(0.6~2.0)
Max. power input W
2000 2000
EER or COP W/W 3.23 3.71
Dehumidifying capacity 10
-
³×m³/h 1.8
Power cable H05RN-F 4G 4.0mm
2
Power source N, V, Hz
1PH, 220-230V~, 50/60Hz
Running /Max.Running current A / A 6.6(2.3-9.5)/9.5 7.0(2.39.5)/9.5
Start Current A 3
Indoor
unit
Unit model (color) AD18MS1ERA
Fan
Type × Number CENTRIFUGALX2
Speed(H-M-L) r/min 700/610/520
Fan motor output/ input power W 70/105
Air-ow(H-M-L) m³/h 920/750/580
ESP Pa 10/30(default)/50/70
Heat exchanger
Type / Diameter mm inner grooved pipe/φ7.0
Row 2
Total Area m² /
Dimension
External(L×W×H) mm×mm×mm 957/655/250
Package(L×W×H) mm×mm×mm 1170/860/340
Drainage pipe (material , I.D./O.D.) mm
PVC 25/29
Controller
(O-Optional,S-Standard)
Wired YR-E16(O)/YR-E17(S)
Fresh air hole dimension mm 145
Electricity Heater kW NONE
Sound power Noise level (H-M-L) dB(A) 57
Sound pressure Noise level (H-M-L) dB(A) 36/33/29
Pipe
Liquid Pipe(mm)
6.35
Gas Pipe(mm)
12.7
Connecting Method
ared
Weight (Net / Shipping) kg / kg 26.5/34
cooling Pdesignc(kW): 5.0KW SEER/CLASS 6.1/A++ QCE(Annual electricity consumption for cooling)kWh: 291
heating
Average Pdesignh(-10
o
C) 4.5KW SCOP/CLASS 4.0/A+ QHE(Annual electricity consumption for heating)kWh: 1782
Warmer Pdesignh(2
o
C) 5.0KW SCOP/CLASS 4.4/A++ QHE(Annual electricity consumption for heating)kWh: 1596
Colder Pdesignh(-22
o
C) / SCOP/CLASS / QHE(Annual electricity consumption for heating)kWh: /
Tdesignh
:
-10
℃
Tbivalent:-8
o
C TOL:-15
o
C Elbu:0
Max. cooling
condition
Indoor temperature
:
32
℃
/23
℃
Max. heating condition
Indoor temperature:27
o
C/-
o
C
Outdoor temperature
:
46
℃
/-
℃
Outdoor temperature:24
o
C/18
o
C
Norminal condition: indoor temperature (cooling): 27
o
CDB/19
o
CWB, indoor temperature (heating): 20
o
CDB
Outdoor temperature(cooling): 35
o
CDB/24
o
CWB, outdoor temperature(heating): 7
o
CDB/6
o
CWB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a
sound pressure noise level.