INSTALLATION INSTRUCTIONS
Fig. 28
Screw with
special washer
Round
terminal
Wire
Terminal
board
Screw with
special washer
Round
terminal
Wire
A. Solid wire
Insulation
Strip 25mm
Loop
B. Strand wire
Strip 10mm
Round
terminal
After passing the connection cord and power cable through the insulation tube, fasten it with the cord clamp, as shown in Fig.29
HOW TO FIXED CONNECTION CORD AND POWER CABLE AT THE CORD CLAMP
Fig. 29
Cord clamp
Insulation tube
Use VW-1, 0.5 to 1.0 mm thick, PVC tube as the insulation tube.
1. INDOOR UNIT SIDE
(1) Remove the electric component box.
ELECTRICAL REQUIREMENT
Electric wire size and fuse capacity:
Table 5
ELECTRICAL WIRING
Series
Connection
cord
(mm
2
)
Fuse capacity(A)
MAX
MIN
36
42
3.5
2.5
30
CAUTION
(1) Match the terminal block numbers and connection
cord colors with those of the outdoor unit.
Erroneous wiring may cause burning of the electric
parts.
(2) Connect the connection cords firmly to the terminal
block. Imperfect installation may cause a fire.
(3) Always fasten the outside covering of the connection
cord with the cord clamp.(If the insulator is chafed,
electric leakage may occur.)
(4) Always connect the ground wire.
3.5
2.5
30
INDOOR UNIT SIDE
Fig. 30
Electric component box
Fig. 31
Electric component box
Remove the four tapping
screws.
CAUTION
Do not remove the screws. If the screws
are removed, the electric component
box will fall.