Outdoor Unit
235
Super Match
Item Model 4U30HS1ERA
Function —— Cooling Heating
Rating capacity W 8800 9800
Cooling Pdesign W 8800
Heating pdesign(-10
) W 7100
Rated power input (indoor + outdoor) W 2316 2390
Rated current input (indoor + outdoor) A 10.1 10.4
EER / COP W/W 3.8 4.1
SEER / SCOP W/W 7.0 4.0
Minimum capacity W 1500 1800
Minimum power input W 550 550
Maximum capacity W 9800 10500
Maximum power input (indoor + outdoor) W 3800 3800
Power source —— 1PH, 220-230V~, 50/60Hz
Max. running current (indoor + outdoor) A / A 16.5 16.5
Power facor(under rating power input) —— 99% 99%
Starting current 5
Fuse size (recommended size) A 25
Outdoor
unit
Compressor
Model / Manufacture —— TNB220FLHMC-L / MELCOM
Oil charge and type —— 870CC/ FV50S
Type —— Twin Rotary (DC inverter)
Number —— 1
Fan
Type × Number —— Axial × 1
Speed r/min High 860
Motor output/input power W 100/125
Air-ows (H/M/L) m³/h about 3500
Heat exchanger
Type / Diameter mm TP2M / 7.0
row —— 2
Face area about 0.75
Dimension
(WxDxH)
External mm 948/340/840
Package mm 1 0 4 0/ 4 3 0 /1 0 0 0
Refrigerant control method —— PMVs
Defrosting method —— Automatic by reversible cycle
Crankcase heater power W none
Noise level
Sound power level dB(A) 70
Sound pressure level dB(A) 56
Weight Net / Shipping kg / kg 76/87
Piping
Refrigerant
Type / Charge kg R410A / 3.2
No need to recharge m 40
Recharge g/m 20
Pipe
Liquid mm 4* Φ6.35
Gas mm 3* Φ9.52+1*Φ12.7
Connecting method —— Flared
Between I.D &O.D
Drop between IU & OU m ≤7.5
Piping length between IU & OU m ≤10
Total liquid piping length m ≤40
Drop between indoor units m ≤1
Max. drop between IU &OU m 15
Max. drop between indoor units m 5
Max. piping length between IU & OU m 25
Max. total length m 70
Working temperature
Cooling
-10~46
Heating
-15~24
Tdisignh
-10
Tbivalent
-7
TOL
-15
Pto
16W Psb
16W Pck
0W Poff
0W
Cooling
A
Cap/EER
8245W/4.5
Heating
A
Cap/COP
5875W/2.6 Tol
Cap/COP
6787W/2.4
B
Cap/EER
6472W/6.7 B
Cap/COP
4050W/4.0 Tb (Cap/COP
5875W/2.6
C
Cap/EER
4233W/8.5 C
Cap/COP
2421W/5.25 Cd
cooling
0.25
D
Cap/EER
4382W/10.6 D
Cap/COP
2456W/6.4 Cd
heating
0.25
Max. cooling condition
Indoor temperature
32
/23
Max. heating condition
Indoor temperature
27
/-
Outdoor temperature
46
/-
Outdoor temperature
24
/18
kWh/annum 440 kWh/annum-average 2487 kWh/annum-warm
1. The above performance data are from the combination of 4U30HS1ERA+4*AS09ZS2ERA.
2. Large drop and long piping installation will obviously reduce the total capacity.