236
Super Match
Item Model 5U34HS1ERA
Function —— Cooling Heating
Rating capacity W 10000 10700
Cooling Pdesign W 10000
Heating pdesign(-10
) W 8100
Rated power input (indoor + outdoor) W 2770 2675
Rated current input (indoor + outdoor) A 12.1 11.6
EER / COP W/W 3.6 4.00
SEER / SCOP W/W 7.0 4.0
Minimum capacity W 1500 1800
Minimum power input W 550 550
Maximum capacity W 11000 11500
Maximum power input (indoor + outdoor) W 4000 4000
Power source —— 1PH, 220-230V~, 50/60Hz
Max. running current (indoor + outdoor) A / A 17.4 17.4
Power facor(under rating power input) —— 99% 99%
Starting current 5
Fuse size (recommended size) A 25
Outdoor unit
Compressor
Model / Manufacture —— TNB220FLHMC-L / MELCOM
Oil charge and type —— 870CC/ FV50S
Type —— Twin Rotary (DC inverter)
Number —— 1
Fan
Type × Number —— Axial × 1
Speed r/min High 900
Motor output/input power W 100/125
Air-ows (H/M/L) m³/h about 4000
Heat exchanger
Type / Diameter mm TP2M / 7.0
row —— 2
Face area about 0.75
Dimension
(WxDxH)
External mm 948/340/840
Package mm 1040/430/1000
Refrigerant control method —— PMVs
Defrosting method —— Automatic by reversible cycle
Crankcase heater power W none
Noise level
Sound power level dB(A) 70
Sound pressure level dB(A) 58
Weight Net / Shipping kg / kg 77/88
Piping
Refrigerant
Type / Charge kg R410A / 3.4
No need to recharge m 40
Recharge g/m 20
Pipe
Liquid mm 5* Φ6.35
Gas mm 4* Φ9.52+1*Φ12.7
Connecting method —— Flared
Between I.D &O.D
Drop between IU & OU m ≤7.5
Piping length between IU & OU m ≤10
Total liquid piping length m ≤40
Drop between indoor units m ≤1
Max. drop between IU &OU m 15
Max. drop between indoor units m 5
Max. piping length between IU & OU m 25
Max. total length m 80
Working temperature
Cooling
-10~46
Heating
-15~24
Tdisignh
-10
Tbivalent
-7
TOL
-15
Pto
16W Psb
16W Pck
0W Poff
0W
Cooling
A
Cap/EER
9825W/4.4
Heating
A
Cap/COP
7149W/2.8 To l
Cap/COP
6875W/2.7
B
Cap/EER
6908W/6.7 B
Cap/COP
4065W/3.81 Tb
Cap/COP
7149W/2.8
C
Cap/EER
5643W/8.9 C
Cap/COP
2890W/5.3 Cd
cooling
0.25
D
Cap/EER
4642W/10.0 D
Cap/COP
2590W/6.0 Cd
heating
0.25
Max. cooling condition
Indoor temperature
32
/23
Max. heating condition
Indoor temperature
27
/-
Outdoor temperature
46
/-
Outdoor temperature
24
/18
kWh/annum 500 kWh/annum-average 2836 kWh/annum-warm
1. The above performance data are from the combination of 5U34HS1ERA+4*AS09ZS2ERA.
2. Large drop and long piping installation will obviously reduce the total capacity.