111
Item Model
4U75S2SR2FA
Function - Cooling Heating
Rating Capacity W 7500 8600
Cooling Pdesign W 7500
Heating Pdesign (-10°C) W 6300
Rated Power Input (Indoor + Outdoor) W 2000 2150
Rated Current Input (Indoor + Outdoor) A 9.1 9.5
EER/COP W/W 3.8 4.0
SEER/SCOP W/W 7.0 4.0
Minimum Capacity W 2400 3100
Minimum Power Input W 550 550
Maximum Capacity W 8700 10000
Maximum Power Input (Indoor + Outdoor) W 3400 3100
Power Source - 1PH, 220-240V~, 50/60Hz
Max. Running Current (Indoor + Outdoor) A / A 14.6 13.5
Power Facor (Under Rating Power Input) - 99% 99%
Starting Current A 5
Fuse Size (Recommended Size) A 25
Outdoor Unit
Compressor
Model/Manufacture - TVB220FAEMC-L/MELCOM
Oil Charge and Type - 870CC/FW68S
Type - Twin Rotary (DC Inverter)
Number - 1
Fan
Type × Number - Axial × 1
Speed r/min High 770
Motor Output/Input Power W 90/130
Air-Flows (H/M/L) m³/h About 4000
Heat Exchanger
Type/Diameter mm TP2M / 7.0
Row - 2
Face Area About 0.6
Dimension
(WxDxH)
External mm 890/340/700
Package mm 998/443/770
Refrigerant Control Method - PMVS
Defrosting Method - Automatic by Reversible Cycle
Crankcase Heater Power W None
Noise Level
Sound Power Level dB(A) 68
Sound Pressure Level dB(A) 55
Weight Net/Shipping kg / kg 61/65