180
2. Tools and materials that may be used with R32 with some restrictions
Tools/Materials Use Notes
Gas leak detector Detection of Gas Leaks
The Ones for HFC Type Refrigerant
May be Used.
Vacuum Pump Vacuum Drying
May be Used if A Reverse Flow
Check Adaptor is Attached.
Flare Tool Flare Machining of Piping
Chages Have Been Made in the
Flare Machining Dimension. Refer to
the Next Page.
Refrigerant Recovery Equipment Recovery of Refrigerant
May be Used if Designed for Use
With R32
Tools for R32 must be handled with special care, and keep moisture and dust from entering the cycle.
R32 leakage Test
No changes from the conventional method. Note that a refrigerant leakage detector for R22 or R410A cannot detect
R32 leakage.
Items to be Strictly Observed:
1.Pressurize the equipment with nitrogen up to the design pressure and then judge the equipment's air tightness,
taking temperature variations into account.
2.When investigating leakage locations using a refrigerant, be sure to use R32.
3.Insure that R32 is in a liquid state when charging.
Reasons:
1.Use of oxygen as the pressurized gas may cause an explosion.
2.Charging with R32 gas will lead the composition of the remaining refrigerant in the cylinder to change and then
this refrigerant can not be used.
Halide torch
R22 or R407C leakage detector
3. Tools and materials that are used with R410A that can also be used with R32
Tools/Materials Use Notes
Vacuum Pump With a Check Valve Vacuum Drying
Bender Bending Pipes
Torque Wrench Tightening Flare Nuts
Only Φ12.70 (1/2'') and Φ15.88
(5/8'')have a larger are machining
dimension.
Pipe Cutter Cutting Pipes
Welder and Nitrogen Cylinder Welding Pipes
Refrigerant Charging Meter Refrigerant Charging
Vacuum Gauze Checking Vacuum Degree
4.Tool and materials that must not used with R32
Tools/Materials Use Notes
Charging Cylinder Refrigerant Charging
Must Not be Used With R32-Type
Units.

Other manuals for Haier AD35S2SM3FA