223
Smart Power
Sleeping. This icon is displayed when setting the
sleeping, and left time of sleeping is displayed by
Heat Reclaim Ventilation, This icon is displayed
when setting the heat reclaim ventilation.
Electrical Heating. This icon will display when
electrical heating is set on DC wired controller.
Intelligent Mode.
Cooling Mode.
Heating Mode.
Fan Mode.
Dry Mode.
Low Fan Speed.
Medium Fan Speed.
High Fan Speed.
If the fan speed is set in auto fan, it will change in the
following sequence: Low→Medium→High→Low, AUTO icon
will display simultaneously.
7.1
Operation
Dip Switch Interpretation (for AC)
DIP
switch
On/Off
station
Function
Default
setting
Sw1
On Slave wired controller
Off
Off Master wired controller
Sw2
On Ambient temp. display on
Off
Off Ambient temp. display off
Sw3
On
Collect ambient temp. from PCB of
indoor
Off
Off
Collect ambient Temp. from wired
controller
Sw4
On Non-volatile memory invalid
Off
Off Non-volatile memory valid
Sw5
On Fahrenheit
Off
Off Celsius
Sw6
On reserved
Off
Off reserved
Sw7
On
Model with Up/Down and Left/Right
swing
Off
Off Model with Up/Down swing
Sw8
On Fresh Air unit
Off
Off General unit