AS24GS1/2ERA 1U24GS1ERA-SM Function and Control
Domestic Air Conditioner
29
5.3 Value of Thermistor
5.3.1 intdoor Unit
Room sensor and Pipe Sensor
R25ć=10KΩ±3%
B25ć/50ć=3700K±3%
Temp.(( ))ć Max.(KΩ) Normal(KΩ) Min.(KΩ) Tolerance( )ć
-30 165.2170 147.9497 132.3678 -1.94 1.75
-29 155.5754 139.5600 125.0806 -1.93 1.74
-28 146.5609 131.7022 118.2434 -1.91 1.73
-27 138.1285 124.3392 111.8256 -1.89 1.71
-26 130.2371 117.4366 105.7989 -1.87 1.70
-25 122.8484 110.9627 100.1367 -1.85 1.69
-24 115.9272 104.8882 94.8149 -1.83 1.67
-23 109.4410 99.1858 89.8106 -1.81 1.66
-22 103.3598 93.8305 85.1031 -1.80 1.64
-21 97.6556 88.7989 80.6728 -1.78 1.63
-20 92.3028 84.0695 76.5017 -1.76 1.62
-19 87.2775 79.6222 72.5729 -1.74 1.60
-18 82.5577 75.4384 68.8710 -1.72 1.59
-17 78.1230 71.5010 65.3815 -1.70 1.57
-16 73.9543 67.7939 62.0907 -1.68 1.55
-15 70.0342 64.3023 58.9863 -1.66 1.54
-14 66.3463 61.0123 56.0565 -1.64 1.52
-13 62.8755 57.9110 53.2905 -1.62 1.51
-12 59.6076 54.9866 50.6781 -1.60 1.49
-11 56.5296 52.2278 48.2099 -1.58 1.47