AS24GS1/2ERA 1U24GS1ERA-SM Service Diagnosis
Domestic Air Conditioner
72
7.3.8 Communication error between the indoor and outdoor units
/
W)B((-/BC.L4EJ// /// /// /// // S[˗
@G,B((-:/BC.L4EJ˖ LED1 flash 15 times
/
/
8*,A(B/(K
/ / / / / / / /
The date received from the another unit in indoor unit-outdoor unit signal
/
transmission is
8E4KG)+,C()/
/ / / / /
checked whether is normal
/
Detection
Malfunction
/ / / /
When the date sent from the another unit cannot be received normally,or when the content
Decision
/ / / / / / / / /
of the data is abnormal
Conditions
/ / /

Supposed
/ / / / / / / /
Ƶ
/ /
indoor unit- outdoor unit signal transmission error due to wiring error
Causes
/ / / / / / / / / /
Ƶ
/ /
Faulty PCB
P-(GM4*.A((,C)D/// /
X/"EG,C()/ /
Be sure to turn off power switch before connect or disconnect connector,
or else parts damage may be occurred.
NO
˄A˅
Restart the a/c and it
becomes normally.
If starting up normally, but
malfunction occurs again
after a while
Check whether the linking cable
between the indoor and outdoor
is well connected or whether its
core wires are well insulated.
Yes
Yes
Yes
No
No
The outdoor mainboard needs
dehumidification.
The outdoor mainboard
needs dedust.
1. Reconnect the linking cable;
2. Replace the linking cable with
new one.