EasyManua.ls Logo

Haier ES15V-Q1(R) - Servicing Procedures; Remove Outer Shell; Change Temperature Controller

Haier ES15V-Q1(R)
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
Model No: ES15V-Q1(R)
Issue
Rev.
No
v
.2014
A
3.Servicing Procedures
3.1 Remove the shell.
Before maintenance, the shell should be removed.
Firstly, take off the red and blue rings; then remove four screws, after that the shell can be
removed,
Attention to the snap joint, Don’t break them.


UnfoldtheshellRemovethefoamcushion
3.2ChangeTemperatureController(thermostat)

1. Remove the knob
2. Remove two screws and remove
temperature controller
Join screw
Temperature control Knob Remove the screws