111
FlexFit Pro
ENGLISH
Dip Switch
Wired Controller Wiring Instructions
WIRED CONTROLLER INSTALLATION
Dimensions
Unit: inch (mm)
Dip Switch ON/OFF Function Default Setting
SW1-1
ON Set as the slave controller
OFF
OFF Set as the master controller
SW1-2
ON Ambient temp. display available
OFF
OFF Ambient temp. display unavailable
SW1-3
ON Display ambient temp. from PCB of indoor
OFF
OFF Display ambient Temp. from wired controller
SW1-4
ON Auto-restart invalid
OFF
OFF Auto-restart valid
SW1-5
ON Fahrenheit
OFF
OFF Celsius
SW1-6
ON Swing angle adjustment available
OFF
OFF Swing angle adjustment unavailable
SW1-7
ON Up/Down and Left/Right swing
OFF
OFF Up/Down swing
SW1-8
ON Fresh Air unit
OFF
OFF General unit