38
FlexFit Pro
2. Specications
Model Name
System AM24LP
Outdoor
1U24LP2VHA
Indoor AM24LP2VH*
Cooling
Rated Capacity Btu/hr 24000
Capacity Range Btu/hr 6800-30700
Rated Power Input W 2,182
SEER 17
EER 11
Moisture Removal Pt./h 5.1
Heating
Rate Heating Capacity 47°F Btu/hr 26500
Heating Capacity Range Btu/hr 6800-34100
Rated Power Input W 2,089
HSPF 11
Operating Range
Cooling °F(°C) 0~115F(-18-46C)*
Heating °F(°C)
-4°F~75°F
-20-24
℃)
Power Supply Voltage, Cycle, Phase V/Hz/- 208-230/60/1
Outdoor Unit
Compressor Type DC Inverter Driven Rotary
Maximum Fuse Size A 25.0
Minimum Circuit Amp A 21.0
Outdoor Fan Speed RPM 750/700/650/600/500/400/300
Outdoor Noise Level dB 47
Dimension: Height in (mm)
38 (965)
Dimension: Width in (mm) 37 3/8(950)
Dimension: Depth in (mm) 14 5/8(370)
Weight (Ship/Net)- lbs (kg) 202.8/ 176.4 (92/80)
Indoor Unit
Fan Speed Stages 4 + Auto
Airow (Turbo/High/Med/Low/Quiet) CFM
845/670/530/470
Motor Speed (Turbo/High/Med/Low/Quiet) RPM
950/860/760/700
Indoor Sound Level dB (Turbo/High/Med/Low/Quiet)
38/35/32/29
Dimension: Height in (mm) 9 7/8 (250)
Dimension: Width in (mm) 37 5/8 (957)
Dimension: Depth in (mm) 25 3/4 (655)
Max. External Static Pressure in.W.G(Pa) 0.6(150)
Drainpipe Size O.D. in 1 1/4
Internal Condensate Pump Standard
Max. Drain-Lift height in(mm) 27 9/16(700)
Grill Model
NA
Grill Dimension: Height in (mm)
NA
Grill Dimension: Width in (mm)
NA
Grill Dimension: Depth in (mm)
NA
Weight (Ship/Net)- lbs (kg)
"81.1/68.8
(36.8/31.2)"
Refrigerant Lines
Connections Flare
Liquid O.D. in 3/8
Suction O.D. in 5/8
Factory Charge Oz 88.2
Maximum Line Length Ft / m 165/50
Maximum Height Ft / m 100/30