3.SAFETY PRECAUTIONS 
4.ELECTRICAL CONTROL DEVICES   
THERMOSTATS  
e 
n 
RELAYS 
HEATER CONTACTOR 
5. APPLICATION 
which  controls the heater. 
The coil uses 24 volts but the contacts carry line voltage .The heater contactor is a large relay,  
There are similar overloads in the indoor air handling portion with the electric resistance heaters. The 
NOTE: Never disconnect or wire around a safety device. First determine why it opened, then replace it 
with a properly rated part.   
indoor blower motor has an internal overload. The electric elements use two types of protectors, both 
protector and must be replaced upon opening. Limit controls are thermal discs that automatically reset. 
replaceable. Some electric heat sections use fusible links. They are a one time over-temperature 
Normally, limit controls open and stop the temperature rise before the fusible links open. 
OVERLOADS AND LIMITS 
ƽ Follow the manufacturer’s instructions when making repairs, installing replacement parts and 
ƽ Use only authorized factory parts.
ƽ Always use industry-recognized service practices in the maintenance, adjustment and repair of the
products covered in this manual.
ƽ Always wear safety glasses when handling refrigerant and peforming brazing operations. 
CAUTION: please read all instructions prior to 
installing, operating, maintaining or repairing the  
product.
WARNING: THE MANUFACTURER’S WARRANTY DOES NOT COVER DAMAGE TO CAUSED BY 
THE USE OF ANSUTHORIZED COMPONENTS OR ACCESSORIES, THE USE OF SUCH 
UNAUTHORIZED COMPONENTS OR ACCESSORIES MAY ENDANGER LIFE AND  
OR INJURY RESULTING FROM THE USE OF SUCH UNAUTHORIZED COMPONENTS OR 
PROPERTY. THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY FOR SUCH LOSS  
ACCESSORIES
performing system maintenance. 
In the cooling mode, the thermostat calls for cooling by energizing the compressor contactor and the
indoor blower control. The indoor blower can operate continuously by setting the thermostat subbase fan
switch to the “ON” position. 
subbase selection information found in the wiring diagram booklet. 
various manual changeover, auto changeover and set-back thermostats or see the thermostat and  
accessible by the consumer. Contact your local distributor for information on part numbers of 
Thermostats are the most obvious control in the air conditioning system because these controls are  
Generally relays used in air conditioning use 24VAC coils. Contact voltage may be either low or line voltage.
Relays provide a method for control switching. Relays may switch either low(24VAC) or line voltage. 
Before specifying any air conditioning equipment, a survey of the structure and a heat gain calculation 
The cooling load calculation determines the unit size. There are two capacities that enable the 
must be made. A heat gain calculation involves identifying all surfaces and openings that gain heat from 
the surrounding air and quantifying that heat gain. The heat calculation also calculates the extra  
heaty load caused by sunlight and by humidity removal. These factors must be considered before 
selection an air conditioning system to provide year round comfort. The Air Conditioning Contractors 
cooling load.
of America (ACCA) J Manual method of load calculation is one recognized procedure for determining the 
Sensible heat is the heat energy
 measured on the dry bulb thermometer. 
equipment to provide comfort. The first is sensible capacity.
 5 