Function
cooling heating
Capacity BTU/h
42600 /
Capacity kW
12.5 /
Sensible heat ratio
75% /
W
4700 /
W
5700 /
EER or COP W/W
2.66 /
Dehumidifying capacity
10‐³×m³/h
Power cable section
Signal cable section
Connecting cable section
Power source N, V, Hz
A / A
Start Current A
Class of anti electric shock
I
/
Max. operating pressure of heat side Mpa
2.8 /
Max. operating pressure of cold side Mpa
2.8 /
Unit model (color)
Type × Number
Speed(H-M-L) r/min
Fan motor output power kW
Air-flow(H-M-L) m³/h
Standard static pressure Pa
Max.static pressure Pa
Type / Diameter mm
Temp. scope
℃
External
(L×W×H)
mm×mm×mm
Package
(L×W×H)
mm×mm×mm
Control type (Remote /wired /model)
dB(A)
kg / kg
Unit model (color)
Model / Manufacture
Oil model
Oil charging
Type
Protection type
Starting method
Type × Number
Speed r/min
Fan motor output power kW
Air-flow(H-M-L) m³/h
Type / Diameter mm
Row / Fin pitch
Temp. scope
℃
External
(L×W×H)
mm×mm×mm
Package
(L×W×H)
mm×mm×mm
Refrigerant control method mm/mm
Noise level dB(A)
kg / kg
Refrigerant Type / Charge g
Liquid mm
Gas mm
Drain hose mm
Connecting Method
m
m
50
item Model
HDU-42CF03/H
Total power input
Pipe
PVC 26/32
Between I.D &O.
MAX.Drop
MAX.Piping length
direct start
Fan
Axial × 1
740±50
0.156
6000
Outdoor unit
HDU-42CF03/H(OUTDOOR)(WHITE)
Compressor
JT160BCBY1L / DAIKIN
SUNISO 4GSDID-K/DAPHNE SE56P
1500-1700
2/1.65
cooling: 43~60 / heating: 6~7
Dimension
1008×410×830
Weight (Net / Shipping)
62/77
Fan
50
Noise level (H-M-L)
55/52/47
SCROLL
Inner thermal protection
WIRED
1197×830×350
1430×940×420
100
TP2M / 9.52x0.36
Indoor unit
HDU-42CF03/H(INDOOR)(WHITE)
Centrifugal × 2
1070±30/860±40/690±50
0.27
1560-2580
Heat exchanger
cooling: 43~60 heating:6~7
Dimension
Heat exchanger
TP2M / 9.52x0.36
3,380-400,50
Max. power input
5.0
cooling 8.2/9.5
Running /Max.Running current
4×0.75mm2
5×2.5mm2
1130×490×930
Capillary tube
Defrosting
Automatic
64
30
Weight (Net / Shipping)
92/100
50
PIPING
R22/3150
9.52
19.05
Flared
Specifications