Rotate the safety valve handle
once a month. The valve
works well if there is water
flowing out, otherwise check
for blocking and replace the
safety valve if necessary.
The appliance contains fluorinated greenhouse gases.
Chemical name of the gas: R134a/ 0,9Kg
Fluorinated greenhouse gases are contained in
hermetically sealed equipment.
Global Warming Potential(GWP) : 1430
Water heaters shall be
equipped with a dedicated
power line and residual
current circuit breakers. The
action current shall not
exceed 30 mA;
Safety instructions (to be followed at any time)
The water drain pipe shall be in connection with the
atmosphere, it shall not be blocked; the water drain pipe
connected to a safety valve shall be installed in a frostless
environment with an continuous downwards inclination.
5
English
In accordance with safety rules, a safety
valve(7bar,99°C,G3/4M) must be installed on the tank. For
France, we recommend hydraulic safety units fitted with a
membrane with the NF marking. The rated pressure of the
safety valve shall not exceed 0.7MPa.
If needed, please refer to the wiring diagram on page 23.
The method of connection about the appliance to the
electrical supply refer to page 21.
5