Instructions on transportation and storage
Functionings & principles
●
1. During transportation or storage, the heat pump water heater shall be packed in the
undamaged package to avoid damage to appearance and performance of the product;
2. During transportation or storage, the heat pump water heater shall be in the upright
position;
3. Under special conditions, this product may be laid down for a short time/distance as
per indication on the side of the package case. The heat pump water heater, after being
laid down for a certain time, shall be kept at upright position for more than 4 hours before
starting up.
The machine shall be kept in the upright position at any time for the best
performance !
into the compressor. As the pressure of the refrigerant increases, so does its
●
temperature. The heated refrigerant runs through a condenser coil within the storage
●
tank, transferring heat to the water stored there. As the refrigerant delivers its heat to the
●
water, it cools and condenses, and then passes through an expansion valve where the
pressure is reduced and the cycle starts over.