Note: 1. Function setting: Pressing the SLEEP button on the remote control
unit for 10 times until hearing 4 sounds from the buzzer on the
panel.
       2. Memory content: Running mode, setting wind speed, setting
temperature, sleep state, flap state.
              3. Cancellation of function: Pressing the SLEEP button on the
              remote control unit for 10 times until hearing 2 sounds from the
                          buzzer on the panel.
(11) Trial run function
When the air conditioner is in OFF state, press the emergency switch
for 5 seconds till hearing 2 sounds of click from the buzzer, then the
air conditioner will turn to the trial run state. The unit will run in the
refrigerating mode and the indoor fan will run in high wind speed mode.
(12) Emergency running mode
       When the air conditioner is in stand-by state, press the emergency
        switch till hearing a sound from the buzzer, then the air conditioner
      will turn to the emergency run state. The rules of emergency run are
            as follows:
    a.Tr>23
o
C, running refrigerating mode, Ts = 26
o
C;
  b.Tr<23
(13) Temperature compensation
There is the function of automatic temperature compensation when
heating, with heating temperature setting = Ts(remote setting) + 4
o
C
(14) Sleeping function
a.After setting the sleeping function, the refrigerating mode and
dehumidification  mode  will  run  as  per  the  following  rules:
b.After setting the sleeping function, the heating mode will run as per the
following rules:
OFF
6hours
3hours
SLEEP
3hours
t(hour)
1hour
1hour
T(
O
C)
T(
O
C)
Ts
Ts
Ts-4
Ts-2
Ts+2
Ts+1
1hour
o
C, running heating mode, Ts = 26
o
C.
Brief introduction to electrical  control function
Domestic Air Conditioner    Model:  HSU-09C03/Z1
HSU-12C03/Z1
Domestic Air ConditionerDomestic Air Conditioner