and medium of wind volume when it is under heating mode.
Modification index table for set temperature
Mode
Content of modification Modified variable Modified parameter
Operation mode modi hp
fication
ETBL0
Forceful
operation modification
ETBL1
Weak wind volume
modification
ETBL2
Heating
Medium wind volume
modification
ETBL3
Operation mode modification ETBL4 Cooling &
moisture
removing
Forceful
operation modification
ETBL5
2.4 temperature level control
2.4.1 Deviation
Work out the deviation of temperature level as follows:
In heating mode: E=(Remote-control set temperature+ modified value)-room
temperature
In cooling & moisture removing mode: E= room temperature -(Remote-control set
temperature + modified value)
2.4.2 Compressor OFF
E is minus and |E|>ΔT
Heating Cooling
ΔT
TCHAHL
TCHACL
afterΔT changes
TCHAHH
TCHACH
condition forΔT changes
The compressor stops after 120 seconds of continuous detection
When the operation starts,according to the table above, the unit will operate
according to the after-the-ΔT-change parameters before the compressor stops
for the first time.
From the time the compressor stops to the time it starts again, the operation will
follow the ΔT (except the moisture removing mode)
When the operation starts and the operation modes change (except when the idle
mode is over) and the deviation is bigger than ΔT, the compressor starts.
When the compressor is working and the remote-controller set temperature falls
below ΔT, the compressor stops.
2.4.3 Compressor operation
When the compressor is kept idle for 3 minutes, the deviation E will be higher
than -T+0.67 and the compressor will start working.
2.4.4 DASH operation
When the operation starts or the operation mode changes (except when the
compressor is switched on after being off), the compressor is on and the indicated
maximum frequency should be as follows:
Models:
HSU-12HS03/R2(DB)
HSU-09HS03/R2(DB)Domestic Air Conditioner
24