. Change the set temperature. With temperature adjusting function 
. The wind volume is the automatic medium 
. When in frost removing mode, the outdoor unit does not accept the 
communication signal for powerful running 
. After 15 minutes of powerful running, the compressor can not be off within 10 
minutes 
4-0-2. Powerful cooling 
Change the set temperature. With temperature adjusting function 
. The wind volume is the automatic strong 
. After the compressor starts, there will be no low-intense running protection within 
3 minutes 
4-0-3
.
There is no powerful mode for wind-sending and moisture  removing 
5.Silent running 
. Send the silent running signal to the outdoor unit 
5-0-1. Silent hearing   
The wind volume is SSLO after the compressor is on 
The wind volume will be kept SSLO within 20 seconds after the compressor stops 
and then changes to weak 
5-0-2. Silent cooling 
The wind volume is SSLO 
5-0-3
.
 There is no silent mode for moisture removing and wind-sending. 
 
6. Timed running 
.
 Set the time duration according to the time difference between the clock for 
timing and the current clock 
. In timing mode, the display panel will flash the light at fixed times 
6-0-1. Timed OFF 
When this function is set, operation modes on the panel display will not change. 
The timing icon will show and the operation stops when the set time comes. 
6-0-2. Timed ON 
When this function is on, the panel display will only show a timing icon. The unit 
will operate as the set mode when the time comes. 
6-0-3
.
  Timed ON/OFF 
The unit will start operating or stop according to the order of your setting.         
 
 
 
7. Automatic running 
7-1.
 Automatic running mode 
Under this
 mode, the MCU will choose the work mode according to the room 
temperature so as to keep the set termperature ( set 23
℃
 for heating mode and 
26
℃
 for cooling mode) 
When the unit is powered on for the first time and the the room termperature is equal to or 
below 23
℃
, it will start the heating mode or the cooling mode when the room temperature is 
higher than 23
℃
 
Enter into the heating mode and follow the heating process(supposed temperature 23
℃
). 
When the temperature is high enough to stop the compressor, the compressor stops and there 
30
 