HSU09/12XHK-SM
Appendix
Domestic Air Conditioner
63
10.2.2 Outdoor wiring diagram of HSU09XHK
NOTE:
(marked with @) on simple cool type.
from BR (marked with @@)on terminal
No dotted line wire is connected
block to 3.
2.There are no dotted lines
1.See above for wiring of
YELLOW/GREEN
RED
WHITE
BROWN
BLACK
BLUE
CAPACITOR
BL:
cool-warm type.
Y/G:
R:
W:
BR:
B:
W(R)
B(C)
R(S)
TERMINAL
COMPRESSOR
FAN
MOTOR
5 6 7
R
R
CAPACITOR
W
B
COMP
R
C
S
-ING
BL
@
BL
@
REVERS
W
VALVE
BLOCK,INDOOR
TERMINAL
1
2
BLOCK,OUTDOOR
1
TERMINAL
2
5
3
4
4
3
B
N
L
WIRING DIAGRAM OF SPLIT UNIT,OUTDOOR
0010544566
@@
@@
BR
W
B
BR