Drawing for the installation of indoor and outdoor units
Necessary Tools for Installation
Hammerƽ
Torque wrench
ƽ
(17mm,22mm,26mm)
Nipperƽ
Reamerƽ
Hacksawƽ Pipe cutterƽ
Gas leakage detector orƽ
soap-and-water solution
Hole core drillƽ Flaring toolƽ
Spanner(17,19 and 26mm)ƽ Knifeƽ
Measuring tapeƽ
ƽ
ƽ
ƽ
ƽ
ƽ
Place where the distance of more than lm from televisions, radios, wireless apparatuses
and fluorescent lamps can be left.
ƽ
In the case of fixing the remote controller on a wall, place where the indoor unit can
receive signals when the fluorescent
ƽ
lamps in the room are in use.
ƽ
ƽ
Place, where discharged wind and noise do not cause a nuisance to the neighbors.ƽ
Place, where a distance markedƽ
Q
isavailableasillustratedintheabovefigure.
Before inserting power plug into receptacle, check the voltage without fail.
The
power
source is the same as the
ƽ
corresponding name plate.
Install an exclusive branch circuit of the power.
ƽ
A receptacle shall be set up in a distance where the power cable can be
reached.
Donotextendthecablebycuttingit.
ƽ
Selection of Installation Place
Power Source
Preparation
NO.0010536243
Installation Manual of Room Air Conditioner
ThemodelsadoptHCFCfreerefrigerantR410A
Indoor Unit - Select a plocation that is
Outdoor Unit - Select a plocation that is
Robust not causing vibration, where the body can be supported sufficiently.
Not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.
Possible to drain easily, where piping can be connected with the outdoor unit.
Where cold air can be spread in a room evenly.
Nearby a power receptacle. (Refer to drawings).
Not less affected by rain or direct sunlight and is sufficiently ventilated.
Strong enough to bear the unit, where vibration and noise are not increased.
Please be subject to the actual product purchased , the above picture is just for your reference.
Read this manual before installation
Explain suf
ciently the operating means to the user according to this manual.
Optional parts for piping
Non-adhesive tape
Adhesive tape
Saddle(L.S)withscrews
Connecting electric cable
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
Floor xing dimensions of the
outdoor unit (Unit:mm /
inch)
Fixing of outdoor unit
Fix the unit to concrete or block
with bolts (10mm) and nuts rmly
and horizontally.
When
tting the unit to wall
surface, roof or rooftop, x
asupportersurelywithnails
or wires in consideration of
earthquake and strong wind.
If vibration may affect the
house, x the unit by attaching a
vibration-proof mat.
The marks from to
in the
gure are the
parts numbers.
Thedistancebetween
theindoorunitandthe
oorshouldbemore
than 2m.
more than
10cm
more than 10cm
more than 10cm
more than 20cm
more than 15cm
more than 25cm
more than
60cm
A
G
A
F
C
E
D
G
B
Arrangement of piping
directions
Rear left
Left
Rear
right
Right
Below
Attention must be paid to
the pitch of drain hose
A
C
184
580
184
083
For:
HSU24VCK-W
(3 7/8)
(3 7/8)
(3 7/8)
(7 7/8)
(23 5/8)
(9 7/8)
(5 7/8)
(4 1/2)
For:HSU18VCK-W
(24 7/8)
(4 1/2)
(13 1/2)
113.5
113.5
633
340
(14 15/16)
(7 1/4)
(22 7/8)
(7 1/4)