18
Component Names Control Panel
HYCD-282
11
Foaming door
Door alarm switch
Door lock
FootCaster
Control panel
Door handle
Door lock
Shield in
front of cabin
USB interface
Component Names
Alarm
Phenomenon
Indication
Buzzer alarm
High
temperature
Low
temperature
Power
failure
Environment
temperature
is high
Sensors
abnormal
Indicator will flash
Alarm indicator flashes,
the blank screen of
display screen and
actual cabinet
temperature display
alternately
It is set by default
that buzzer alarm will
start 2h after first
boot, for normal
operation, buzzer
alarm will delay
15min
Buzzer alarm
delays 30s
------------
Buzzer alarm
When the cabinet
temperature is higher
than the setting value
of high temperature
alarm
Power failure of
refrigerator-freezer
Environment
temperature is higher
than 38°C
Main sensor failure in
refrigerator-freezer
When the cabinet
temperature is lower
than the setting value
of low temperature
alarm
Main sensor failure in
refrigerator
Environment
temperature sensor
failure
Battery power
shortage or battery
switch not open
Buzzer alarm
------------
------------
Buzzer alarm
Low
battery
Fault code
E9
E10
/
E14
E6
E3
E0
E5
Indicator lights on
Refrigerating
chamber door is
opened or not closed
well for over 15min
Door
opening
alarm
/ Indicator will flash
Indicator will flash
Indicator will flash
Indicator will flash
Indicator will flash
Indicator will flash