Maintenance
Nozzle Cleaning and Alignment
To keep your HaloFogger® working at optimum performance, it is recommended that you clean the nozzle
on a regular basis (example: clean nozzle once-a-week if fogger is used once-a-day or more.)
Step 1. Before performing any maintenance to the HaloFogger, disconnect the power cord from the
electrical outlet.
Nozzle Insert
Main Bolt
IMPORTANT - Position Main Bolt so a uniform gap
surrounds the nozzle tip.
Step 2. Remove Nozzle. Using a 5/8” wrench, carefully
turn nozzle counter-clockwise 90º and remove.
Step 3. Separate Parts. Remove Main Bolt from Nozzle
Insert. Soak both parts in soap and water. Rinse parts
thoroughly with water.
Step 4. Reassemble Nozzle. Carefully insert the Main
Bolt back into the Nozzle Insert. Make sure the “wings” on
the Main Bolt nest into the slots down inside the Nozzle
Insert.
Step 5. Carefully reinstall the nozzle into the Halo,
turning nozzle clockwise 90º to lock into place. Test Halo
for straightness of nozzle stream.
Funnel Cleaning
The uid funnel inside the HaloFogger should be checked for debris on a regular basis. Visually inspect the
funnel. If any debris is present, wipe with a clean towel dampened with water.
Ensure that the funnel screen is in place.