22 Hamlet Solution Wood & Multifuel Stoves
SERVICING & MAINTENANCE
DISASSEMBLE AIRWASH
The Hamlet Solution air wash may be disassembled
for cleaning or adjustment. To achieve this, the
following procedure should be followed:
Note - This should only be carried out when the fire
is cold and unlit.
•Unscrew (Anti-clockwise) the airwash control
knob (Fig. 14).
•Move outer cover up by tapping each end of the
cover with a soft mallet.
•Lift outer cover free from body, being careful not
to damage the ends of each lug (Fig. 15).
•Slide off the spacer tube from the centre stud and
retain for re-assembly.
•Unscrew the inner slider and clean/replace
(Fig.16).
•Refit using the reverse of this procedure.
FUEL RETAINER BARS -
INSPECTION
Fuel retainering bars are supplied with the stove.
Periodically check for any bowing or heat warpage
to the fuel retaining bars and replace as necessary.
Note: This operation should only be carried out
when the appliance is unlit and cold.
Fig. 14. Unscrew control knob
Fig. 15. Lifting cover from body
Fig. 16. Inner slider removal

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hamlet Solution and is the answer not in the manual?

Hamlet Solution Specifications

General IconGeneral
MaterialSteel
Heat Output5kW
Flue Size125mm
DEFRA ApprovedYes
TypeWood Burning
Flue OutletTop

Related product manuals