MINIVATOR 2000 INSTALLATION MANUAL 37
Appendix 3
Minivator 2000 block schematic – right hand stairlift – MS125
SEAT TO POWERPACK
CONNECTORS
(POWERED OPTIONS ONLY)
MOTOR
BATTERY
ISOLATION
BRAKE
CHARGE
DIAGNOSTIC
DISPLAY
33V CHARGE POSITIVE INPUT VOLTAGE
INTERNAL BEND
SPEED SWITCHES
9 WAY CONNECTOR
8 WAY CONNECTOR
MS125 CONTROLLER
5A
(SEE SEPARATE DOCUMENT
FOR CONNECTIONS)
IR SENSOR 1
SEAT
FINAL
LIMITS
IR SENSOR 2
HINGE SAFETY
SWITCH
SW16
3 WAY
CONN
RED
RED
BLACK
YELLOW
RED
BLACK
YELLOW
SPADE
SPADE
GREEN
DOWN
WHITE
CON-1
CON-1
CON-1
CON-1
CON-1
CON-1
CON-2
CON-2
CON-2
CON-2
CON-2
CON-2
CON-2
1
1
IR 1
IR 2
HINGE
SAFETY I/P
DIAG
CHRG
BRAKE
BK1
BK2
2
1
2
3
1
2
3
2
3
4
5
6
7
8
1
1 1
5
4
3
2
1
4
3
2
1
2
3
4
5
6
7
8
9
1
1
1
BLUE
TOGGLE COMMON
BROWN
UP
YELLOW
BOTTOM SAFE-EDGE
GREY
SAFE-EDGE COMMON
E-STOP & KEY DETECT
YEL/BLK STRIPE
VIOLET
TOP SAFE-EDGE
ORANGE
ORANGE
BATT
BK
BK
+
+
+
+
+
-
-
-
-
-
BATT
BATT
BATT
BLACK
BLACK
BLACK
M+
M-
WHITE
RED
BATT
BATT
BATT
MOTOR
M2
M1
MOTOR
BOTTOM LIMIT
BLUE
TAG
BLUE
TAG
YELLOW
TAG
YELLOW
YELLOW
WHITE
BROWN
BROWN
BROWN
BULLET
BULLET
ORANGE
ORANGE
ORANGE
VIOLET
GREY
BROWN LOOP
6
5
4
3
2
1
2
1
2
1
1
2
2
1
2
1
1
1
1
1
1
1
2
1
6
5
4
3
2
1
VIOLET
GREY
BROWN
RED
RED
RED
YELLOW
TAG
RED
TAG
RED
TAG
ORANGE
BOTTOM LIMIT
YELLOW
TOP LIMIT
TOP LIMIT
YELLOW
WHITE
WHITE
WHITE
SPADE
SPADE
SPADE
FINAL LIMIT
HINGE FUSED
AV OUTPUT+
AV OUTPUT-
BLK/WHT STRIPE SWITCHED 0V
HINGE DATA
GREY
24VDC
RED
BLACK
1
2
1
2
3
1 1
M F
MF
M
F
M
F
M
F
F
F
M
1 1
ORANGE
SW15
SW11
OSG
SWITCH 2
SW12
OSG
SWITCH 1
SW9
SW5
SW6
SW4
SW7
SW8
SW1
CHASSIS
UNDERPAN EDGE 1
CHASSIS
UNDERPAN EDGE 2
SW2
SW3
SW10
BOTTOM TRUN LIMITS
TOP TRUN LIMITS
FOOTREST UNDERPAN
SAFE EDGE
FOOTREST BOTTOM EDGE
FOOTREST TOP EDGE
COMMON
SW14
SW13
FINAL LIMIT UP
FINAL LIMIT DOWN
(HINGETRACK ONLY)
HINGETRACK
COMMS DATA
CONTACT
TO SEAT
FINAL LIMITS
POWER SWIVEL
DATA CONNECTION
SLIDE ENABLE
PING ENABLE
PLATFORM ENABLE
AUTO HINGE ENABLE
RIGHT HAND LIFT
FAST RAMP
UNUSED
SLIDE DISABLE
DEFAULT OFF
PING DISABLE
PLATFORM DISABLE
LEFT HAND LIFT
AUTO HINGE DISABLE
SLOW RAMP
UNUSED
DIP 1
DIP 2
1
ON
2 3 4 1
ON
2 3 4
M F
= PUSH-ON CONNECTOR
= MULTI-PIN CONNECTOR
ALL SAFETY CIRCUITS SHOULD
BE NORMALLY CLOSED
ABOVE DIP SETTINGS ARE FOR BASIC RH LIFT
FOR OTHER SETTINGS – REFER TO SEPARATE DOCUMENTATION
KEY:
E-STOP DETECT
CHARGE NEGATIVE THROUGH CHASSIS
1A
25A
4
3
2
1