4.3 You push on the infusion valve, but no pressure comes out
You have a problem with the manometer
-change the manometer sub assembly (page 14)
The aluminium body is dirty inside
-Change the machine
4.4 You push on the infusion valve, the pressure comes out but not the water
You have a problem with the water tank (little crack between 2 screws)
-Change the infusion chamber (page 18)
4.5 There is a water leakage by the infusion shaft
You have a sealing problem in the infusion chamber
2 solutions:
-Change the infusion chamber (page 18)
-Change the pod holder (page 21)
4.6 There are splashes between the portafilter and the water tank
You have a sealing problem
-Change the 50mm o-ring
Is the pod holder going out easily?
2 solutions:
-Change the infusion chamber (page 18)
- Change the pod holder (page 21)
4.7 The pod holder fall out
2 solutions:
-Change the infusion chamber (page 18)
-Change the pod holder (page 21)
4.8 The knob is broken
-Change the infusion shaft (page 23)