EasyManua.ls Logo

Hanover DG3 - Appendix B: System Options

Default Icon
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DG3 Controller Installation and Operation
Manual
540846-3 page 53 of 64 25/09/2015
Appendix B: System Options
This appendix lists all functions available in the system and their values selected by using the F/E key:
Option
Possible values
Value by
default
Description
AS - Auto
Speed
2400, 4800, 9600, 19200, 38400,
57600, 115200
57600
Sets transfer speed of sign
firmware updating (for
example, an oled.bin file)
DA - Daylight
Saving
1 = enabled
0 = disabled
1
In Europe (only), the
controller will automatically
adjust clock for daylight
saving.
Adjustment must be made
manually for other territories
(only applies if clock enabled
in both cases).
DP - Date
pos.
1 = UK: date/month/year
2 = USA: month/date/year
1
(31/12/2010)
Position of date and month
(only applies if RTC fitted and
enabled)
KL - Key
Illumination
0 - 100
30
Used to back-illuminate
function keys.
100 = brightest (for dark cab
situations)
LC - Lock
Code
0000 - 9999
0101
Allows lock code to be set
LG -
Language
(ISO 639.2
codes)
DA - Danish
EN - English
FI - Finnish
FR - French
DE - German
ID - Indonesian
IT - Italian
PT - Portuguese
ES - Spanish
SV - Swedish
NO- Norwegian
RO - Romanian
TR - Turkish
ZH - Chinese
NL - Dutch
EN
Determines the language
used by controller (Not all
languages are programmed
into Helen by default)
PF*
Name 0 - Name 99
Name 0
Controller configuration set in
Helen. For more details,
please refer to section 7 in
Helen v3.3 display-editing
software - operating manual