DG3 Controller – Installation and Operation Manual
540846-3 page 63 of 64 25/09/2015
* = All visible parameters are reset,
passenger signs are blank and DG3 enters
into IDLE mode.
If a number is now entered manually, DG3
stays in Local mode and will not respond to
further remote inputs until 0 for destination or
99 for information is entered locally.
0 = No reset: passenger and driver signs
return to their pre-reset state.
1 = Same as * except that locally entered
parameters (but not remotely entered
parameters) are retained after power up.
2 = Returns to last remotely selected
destination, or to IDLE mode if no previous
selected remote location is available.
Resets controller in various ways, depending on whether or not remote control is
enabled.
* and 0 = No reset. Passenger and driver
displays show Destination, Route Number
and Information as normal.
1 and 2 = DG3 reset to IDLE mode.
Passenger displays are blank.
0 = pressing has no effect on controller
display
1 = press and hold : DG3 passes
through ‘Configure’ and ‘Idle’ screens to
show ‘Return’ and ‘Out’ prompts, between
which it then alternates until the button is
released. Destination codes can then be set
for both ‘Out’ and ‘Return’ options.
0 = do not allow
1 = allow
Determines whether or not leading zeros of a route number are shown.
If RZ = 0, leading zeros are deleted (single zero is allowed).