Comparative s prescale value selection
When setting the option setting groupz the menu is displayed and it
is possible to set the decimal setting individually for each bank
When setting the option setting group, the menu is displayed and it
is possible to set the display sampling cycle individually for each
bank.
When setting the option setting group, the menu is displayed and it
is possible to set the hysteresis value individually for each bank.
When setting the option setting group, the menu is displayed and it
is possible to set the time setting value individually for each bank.
3. Setup Group (IN/OUT setting group)
Setting Menu Meaning Description Initial
Input/Output control
setting group selection
Input Operation
Mode Setting
IN A sensor
type setting
IN B sensor
type setting
Output mode setting
IN A s start
compensation timer
setting
IN B s start
compensation timer
setting
IN A s Auto Zero
timer setting
Input/Output setting in the Input/Output control setting group
: NPN Normal Open : NPN Normal Close
: PNP Normal Open : PNP Normal Close
: Contact Normal Open
: NPN Normal Open : NPN Normal Close
: PNP Normal Open : PNP Normal Close
: Normal Open
2. PS Group (Prescale or Time Option Setting Group)
Setting Menu Meaning Description Initial
Prescale Setting
Group Selection
IN A s prescale
mantissa (X) setting
IN A s prescale
exponent (Y) setting
For each bank, the
displayed value s
decimal point setting
For each bank, the
displayed value s cycle
setting
For each bank, the output s
hysteresis setting
(note 8)
For each bank, input
time unit setting
(operation mode
F3, F4, F5, F6)
5. Peak Display Group (Peak Value save Group)
Setting Menu Meaning Description Initial
Peak value save group
1st value of HIGH peak
2nd value of HIGH peak
3rd value of HIGH peak
4th value of HIGH peak
Average value of 4
HIGH peaks
1st value of LOW peak
2nd value of LOW peak
3rd value of LOW peak
4th value of LOW peak
Average value of 4
LOW peaks
Erase the memory of
the peak value
Save the MAX, MIN peak value
of the measured values to the 10 memories
Save the highest number of the measured value
Save the second highest number of the measured value
Save the third highest number of the measured value
Save the fourth highest number of the measured value
Save the average value after taking the average
of the 4 saved HIGH peak values
Save the fourth lowest number of the measured value
Save the third lowest number of the measured value
Save the second lowest number of the measured value
Save the lowest number of the measured value
Save the average value after taking the average
of the 4 saved LOW peak values
Erase all the saved values
Saved values in Peak display group erase all together.
Saved peak values can be erased automatically when mode change or power ON/OFF.
Option setting group)
Setting Menu
Meaning
Description Initial
Option setting group
selection
PV transmission output s
high limit value setting
PV transmission output s
low limit value setting
Communication
id setting
Communication
speed setting
Remote control setting
Power failure
compensation
setting
Parameter lock
setting
Set the option of the input/output setting item
in the option setting group
F1, F2, F7, F8, F9 : 0 ~ 99999
F3, F4, F5, F6 : 0 ~ Set time Lange
Setting Unit : bps
: Remote Control
: Local Operation
: Remote control from the outside (remote)
: Local operation only (Local)
: all mode
cancellation
: P1 ~ P3 Lock
: P2 ~ P4 Lock
: P3 ~ P4 Lock
: P4 Lock
: P1 ~ P4 Lock
: Only for RP3-5A(D)4 4 ~ 20 mA Output
: Only for RP3-5A(D)5 RS 485 Communication