MA0106E081216
Safety Information
Model and Suffix code
Power Supply
Dimensions & Panel Cutout
Counter / Timer
GE Series
Thank you for purchasing HANYOUNG NUX CO,.Ltd. Product.
Please check whether the prouduct you purchased is the exactly
same as you ordered. Before using product, please read
instruction maunal carefully.
INSTRUCTION MANUAL
HEAD OFFICE
1381-3, Juan-Dong, Nam-Gu Incheon, Korea
TEL: (82-32)876-4697 FAX:(82-32)876-4696
Before you use, read safety precautions carefully, and use this product
properly. The precautions described in this manual contains important
contents related with safety; therefore, please follow the instructions
accordingly. The precautions are composed of DANGER, WARNING
and CAUTION.
Do not touch or contact the input/output terminals because they may
cause electric shock.
1. If there is a possibility of an accident caused by errors or
malfunctions of this product, install external protection circuit to
prevent the accident.
2. This product does not contain an electric switch or fuse, so the user
needs to install a separate electric switch or fuse externally. (Fuse
rating : 250 V 0.5 A)
3. To prevent defection or malfunction of this product, supply proper
power voltage in accordance with the rating.
4. To prevent electric shock or devise malfunction of this product, do
not supply the power until the wiring is completed.
5. Since this product is not designed with explosion-protective
structure, do not use it at any place with flammable or explosive gas.
6. Do not decompose, modify, revise or repair this product. This may
cause malfunction, electric shock or fire.
7. Reassemble this product while the power is off. Otherwise, it may
cause malfunction or electric shock.
8. It you use the product with methods other than specified by the
manufacturer, there may be bodily injuries or property damages.
9. Due to the danger of electric shock, use this product installed onto a
panel while an electric current is applied.
1. The contents of this manual may be changed without prior notification.
2. Before using the product you have purchased, check to make sure
that it is exactly what you ordered.
3. Check to make sure that there is no damage or abnormality of the
product during delivery.
4. Do not use this product at any place with corrosive(especially
noxious gas or ammonia) or flammable gas.
5. Do not use this product at any place with direct vibration or impact.
6. Do not use this product at any place with liquid, oil, medical
substances, dust, salt or iron contents. (Pollution level 1 or 2)
7. Do not polish this product with substances such as alcohol or benzene.
8. Do not use this product at any place with excessive induction
trouble, static electricity or magnetic noise.
9. Do not use this product at any place with possible thermal
accumulation due to direct sunlight or heat radiation.
10. Install this product at place under 2,000m in altitude.
11. When the product gets wet, the inspection is essential because
there is danger of an electric leakage or fire.
12. If there is excessive noise from the power supply, using insulating
transformer and noise filter is recommended. The noise filter must
be attached to a panel grounded, and the wire between the filter
output side and power supply terminal must be as short as possible.
13. If gauge cables are twisted closely, the effect on noise may occur.
14. Do not connect anything to the unused terminals.
15. After checking polarity of terminal, connect wires at the correct position.
16. When this product is connected to a panel, use a circuit breaker or
switch approved with IEC847-1 or IEC947-3.
17. Install the circuit breaker or switch at near place for convenient use.
18. For the continuous and safe use of this product, the periodical
maintenance is recommended.
DANGER
WARNING
19. Some parts of this product have limited life span, and others are
changed by their usage.
20. The warranty period for this product including parts is one year if
this product is properly used.
21. When the power is on, the preparation period of contact output is
required. In case of use for signals of external interlock circuit, use
with a delay relay.
CAUTION
Model
GE
Description
S(W)96.0
(H)48.0 (L)107.6
(W)48.0 (H)48.0 (L)84.0
(W)72.0 (H)36.0 (L)81.0
(W)72.0 (H)72.0 (L)87.0
PRESET BATCH
TOTAL (Indicator)
4 : 9999 (4 digit)
GE3,GE7:Not available
6 : 999999 (6 digit)
1 stage
2 stage
Twin timer Support
100 V - 240 V a.c
24 V - 60 V d.c
Digital Batch Counter
GE3
GE4
GE6
GE7
P
T
4
6
1
2
A
D
Appearance
Type
Digit
Stage
Power supply
During the first 100 after power input and first 200 after power
opening, it is consider as ascend and descend time of internal power and
external output power. Therefore, it does not operate during unstable
period in order to prevent from malfunction which is caused by unstable
output operation of external sensor
Supply signal only after 100 following the power input.
Supply power only after 200 following the power shutdown.
GE7
GE4
[Unit : mm]

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HANYOUNG NUX GE Series and is the answer not in the manual?

HANYOUNG NUX GE Series Specifications

General IconGeneral
BrandHANYOUNG NUX
ModelGE Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals